Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/14771

TítuloEffect of ultrasound parameters for unilamellar liposome preparation
Autor(es)Silva, Raquel
Ferreira, Helena
Little, Collin
Paulo, Artur Cavaco
Palavras-chaveLiposome
Sonication
Reactor optimization
Photon-correlation spectroscopy
Zeta-potential measurements
Data2010
EditoraElsevier
RevistaUltrasonics Sonochemistry
Resumo(s)In this study, it was investigated the effects of ultrasound, namely power input, distance from ultrasound tip to base of reactor and treatment time, in the formation of liposomes. Results indicate a dependence on cavitation events that are a function of power input, and consequently dependent on the position of the probe within the reaction vessel and the wave behaviour. Short treatment times are required to achieve nanosized vesicles in anti-nodal (k/4; 19 mm) reactor geometries. In this wave point the cavitation phenomenon is more pronounced when compared with the nodal point (k/2; 38 mm). Therefore, the consideration of the above parameters is vital if dependable and repeatable results are to be achieved.
TipoArtigo
URIhttps://hdl.handle.net/1822/14771
DOI10.1016/j.ultsonch.2009.10.010
ISSN1350-4177
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:DET/2C2T - Artigos em revistas internacionais com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2010 Effect of ultrasound parameters for unilamellar liposome preparation.pdfEffect of ultrasound parameters for unilamellar liposome preparation150,65 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID