Please use this identifier to cite or link to this item:
https://hdl.handle.net/1822/51439
Title: | Comparison of Rhodotorula sp. and Bacillus megaterium in the removal of cadmium ions from liquid effluents |
Author(s): | Rosca, Mihaela Hlihor, Raluca-Maria Cozma, Petronela Dragoi, Elena Niculina Diaconu, Mariana Silva, Bruna Andreia Nogueira Airosa Tavares, T. Gavrilescu, Maria |
Keywords: | Biosorption Cd(II) Microorganisms Modelling Statistical model modeling |
Issue date: | 23-Feb-2018 |
Publisher: | Walter de Gruyter GmbH |
Journal: | Green Processing and Synthesis |
Citation: | Rosca, M.; Hlihor, R.; Cozma, P.; Dragoi, E. N.; Diaconu, M.; Silva, Bruna; Tavares, Teresa; Gavrilescu, M., Comparison of Rhodotorula sp. and Bacillus megaterium in the removal of cadmium ions from liquid effluents. Green Processing and Synthesis, 7(1), 74-88, 2018 |
Abstract(s): | This study compares the capacity of Rhodotorula sp. and Bacillus megaterium for Cd(II) removal considering the influence of operating parameters (pH, biosorbent dosage, contact time, temperature, initial metal concentration in solution). The highest Cd(II) uptake of 14.2 mg/g by Rhodotorula sp. was exhibited at 30°C, when working at pH 6 and with 5 g/l biosorbent dosage, after 48 h of contact time. In these conditions, a removal efficiency of 85% was obtained. Similar outcomes were obtained for B. megaterium (15.1 mg/g, 90%) at 35°C, pH 4 and 3 g/l biosorbent dosage, considered as the optimum set of parameters, equilibrium being achieved for a contact time of 20 min. The possible interaction mechanisms between the biosorbents and Cd(II) were evaluated through point of zero charge (pHpzc), Fourier transform infrared (FTIR), spectroscopy and scanning electron microscopy coupled with energy dispersive X-ray microanalysis (SEM-EDX). Data were modeled using pseudo-first and pseudo-second order kinetic models and Langmuir and Freundlich isotherms models. Further studies considered a modeling approach based on linear regression with Durbin-Watson statistics, while the accuracy and precision of experiments were evaluated by ANOVA. |
Type: | Article |
URI: | https://hdl.handle.net/1822/51439 |
DOI: | 10.1515/gps-2016-0218 |
ISSN: | 2191-9542 |
e-ISSN: | 2191-9550 |
Publisher version: | https://www.degruyter.com/view/j/gps |
Peer-Reviewed: | yes |
Access: | Open access |
Appears in Collections: | CEB - Publicações em Revistas/Séries Internacionais / Publications in International Journals/Series |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
document_47453_1.pdf | 1,34 MB | Adobe PDF | View/Open |