Utilize este identificador para referenciar este registo:
https://hdl.handle.net/1822/52902
Título: | Voxel-based registration of simulated and real patient CBCT data for accurate dental implant pose estimation |
Autor(es): | Moreira, António Herculano Jesus Queirós, Sandro Filipe Monteiro Morais, Pedro André Gonçalves Rodrigues, Nuno F. Correia, André Ricardo Fernandes, Valter Pinho, A. C. Marques Fonseca, Jaime C. Vilaça, João L. |
Palavras-chave: | Dental prosthetics Cone-beam CT simulation Voxel-based rigid registration Computer-aided modelling |
Data: | Fev-2015 |
Editora: | Society of Photo-optical Instrumentation Engineers (SPIE) |
Revista: | Proceedings of SPIE |
Resumo(s): | The success of dental implant-supported prosthesis is directly linked to the accuracy obtained during implant's pose estimation (position and orientation). Although traditional impression techniques and recent digital acquisition methods are acceptably accurate, a simultaneously fast, accurate and operator-independent methodology is still lacking. Hereto, an image-based framework is proposed to estimate the patient-specific implant's pose using cone-beam computed tomography (CBCT) and prior knowledge of implanted model. The pose estimation is accomplished in a threestep approach: (1) a region-of-interest is extracted from the CBCT data using 2 operator-defined points at the implant's main axis; (2) a simulated CBCT volume of the known implanted model is generated through Feldkamp-Davis-Kress reconstruction and coarsely aligned to the defined axis; and (3) a voxel-based rigid registration is performed to optimally align both patient and simulated CBCT data, extracting the implant's pose from the optimal transformation. Three experiments were performed to evaluate the framework: (1) an in silico study using 48 implants distributed through 12 tridimensional synthetic mandibular models; (2) an in vitro study using an artificial mandible with 2 dental implants acquired with an i-CAT system; and (3) two clinical case studies. The results shown positional errors of 67±34μm and 108μm, and angular misfits of 0.15±0.08 and 1.4, for experiment 1 and 2, respectively. Moreover, in experiment 3, visual assessment of clinical data results shown a coherent alignment of the reference implant. Overall, a novel image-based framework for implants' pose estimation from CBCT data was proposed, showing accurate results in agreement with dental prosthesis modelling requirements. |
Tipo: | Artigo em ata de conferência |
Descrição: | "Progress in Biomedical Optics and Imaging, vol. 16, nr. 42" |
URI: | https://hdl.handle.net/1822/52902 |
ISBN: | 978-162841504-9 |
DOI: | 10.1117/12.2082806 |
ISSN: | 0277-786X |
e-ISSN: | 1996-756X |
Arbitragem científica: | yes |
Acesso: | Acesso aberto |
Aparece nas coleções: | CT2M - Publicações em atas de encontros científicos / Papers in conference proceedings DEI - Artigos em atas de congressos internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
94143H.pdf | 419,05 kB | Adobe PDF | Ver/Abrir |