Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/53224

TítuloControl a pneumatic sequence using waterfall method in the LabVIEW plataform
Autor(es)Simões, José
Fernandes, Monteiro
Seabra, Eurico
Palavras-chaveLabView
NI Controller
Waterfall method
Pneumatic sequence
NI USB 6009
Data2016
CitaçãoSimões, J., Fernandes, A., Seabra, E., Control a pneumatic sequence using waterfall method in the LabVIEW plataform, International Conference on Regional Triple Helix Dynamics (HELIX2016), Castelo Branco, June 29-30 and July 1, 2016.
Resumo(s)The project chosen for this paper was one that the student had to construct a program using the LabVIEW platform in which it would control electro pneumatic systems using the waterfall method. As a result a program was created in LabVIEW that would do just that with various other functionalities like an interactive GUI (guided user interface) which is easy to follow and use along with microcontroller communication and programming capabilities. This added functionality allows the user to export the pneumatic code to a microcontroller like the NI USB 6009 (used in this project) and test or execute the code using pneumatic cylinders and end position sensors.
TipoArtigo em ata de conferência
URIhttps://hdl.handle.net/1822/53224
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:CT2M - Artigos em revistas de circulação internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Regional_Helix_2016_paper_36.pdf360,53 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID