Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/66253

TítuloImpact of contact lens materials on the mfERG response of the human retina
Autor(es)Amorim-de-Sousa, Ana
Moreira, Linda
Macedo-de-Araujo, Rute
Amorim, Andre
Jorge, Jorge
Fernandes, Paulo
Queirós, A.
González-Méijome, José Manuel
Palavras-chaveMultifocal electroretinography
Contact lens material
Scleral contact lens
Water content
Electrical conductivity
Data2020
EditoraSpringer
RevistaDocumenta Ophthalmologica
Resumo(s)Purpose To investigate the effect of different hydrophilic and rigid gas-permeable contact lens (CL) materials on multifocal electroretinography (mfERG). Methods The mfERG was recorded in 18 healthy subjects with RETI-port/scan21 (TM): 11 subjects underwent mfERG recording wearing two different hydrophilic CLs with different water contents in a randomized order (1 silicone hydrogel-Comfilcon A, 48%EWC, and 1 hydrogel-Omafilcon A, 62% EWC) and 7 other subjects wore a hydrophobic rigid gas-permeable scleral lens (SL)-Hexafocon A. Control measures were recorded without CL in both groups. mfERG recordings were performed with a stimulus array pattern of 103-scaled hexagons displayed on a 19-inch RGB monitor at 28 cm distance at a frame rate of 60 Hz. The amplitude (nV), implicit time and response density (nV/deg(2)) of the first-order kernel components N1, P1 and N2 were evaluated for the total mfERG response and for the response averages of 4 quadrants and of 6 successive concentric rings. Subjects were optically corrected for the working distance of ERG display. Results Hydrophobic material significantly decreased the P1 amplitude of the total mfERG response, at Rings 3, 4 and 6 and Quadrant 4 (> 53.77 +/- 43.2 nV; P <= 0.050), as well as the total (- 71.59 +/- 50.68 nV) and Ring 6 (- 104.76 +/- 79.88 nV) N2 amplitude (P <= 0.043). N1, P1 and N2 peak times suffered significant changes with both hydrophilic CL (P <= 0.050). Omafilcon A significantly increased P1 amplitude of Ring 5 and N2 amplitude of Ring 4, when compared to baseline (52.40 +/- 71.87 nV; P = 0.036) and to Comfilcon A (39.51 +/- 48.63 nV; P = 0.023), respectively. Conclusions Hydrophobic CL slightly attenuated the strength of the mfERG signal, especially at the middle to peripheral retinal areas, while hydrophilic CL slightly changed the implicit time of the response. Different hydrophilic CL materials might affect the mfERG response differently. When considering the measurement of mfERG obtained with a CL in place, researchers should bear in mind th
TipoArtigo
URIhttps://hdl.handle.net/1822/66253
DOI10.1007/s10633-019-09722-6
ISSN0012-4486
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:ASSESSMENT AND ENHANCING VISUAL PERFORMANCE (2018 - ...)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Amorim-de-Sousa_19_DocOphth (Impact of CL materials mfERG).pdf1,07 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID