TítuloSERS and electrochemical impedance spectroscopy immunoassay for carcinoembryonic antigen
Autor(es)Guerrero, Yuselis
Moreira, Felismina
Ana Sousa-Castillo
Miguel A. Correa-Duarte
Sales, M. G. F.
Palavras-chaveCarcinoembryonic Antigen
Immunosensor
Electrochemical impedance spectroscopy
Screen-printed electrode
Surface-enhanced Raman spectroscopy
Data10-Jan-2021
EditoraElsevier
RevistaElectrochimica Acta
CitaçãoGuerrero, Yuselis; Moreira, Felismina; Ana Sousa-Castillo; Miguel A. Correa-Duarte; Sales, M. G. F., SERS and Electrochemical Impedance Spectroscopy Immunoassay for carcinoembryonic antigen. Electrochimica Acta, 336(137377), 2021
Resumo(s)This work describes an innovative dual detection approach, combining electrochemical and surface-enhanced Raman scattering (SERS) sequential readings, on the same sensing surface. This was achieved by establishing (i) an antibody binding stage on a suitably modified screen-printed electrode (Au-SPE), to produce an electrochemical signalling system, followed by (ii) a second antibody binding stage, on the same sensing surface, comprising gold nanostars (AuNS) with a suitable Raman reporter, and acting as a second signalling system (SERS). This simple principle is applied herein to carcinoembryonic antigen (CEA) detection. The first layer of antibodies was assembled on the Au-SPE previously modified with a cysteamine layer. Binding to CEA was allowed for 30 minutes. Electrochemical impedance spectroscopy (EIS) readings followed the several stages of Au-SPE modification and generated analytical data. After, the AuNS were modified with 4-aminothiophenol (4-ATP)/Ab-CEA, and incubated on the same sensing surface, to provide SERS data. The analytical features were checked for both EIS and SERS. In EIS, the sensor showed linear response range from 0.25 to 250 ng/mL, with a linear correlation coefficient of 0.991, evaluated in serum. It also demonstrated good selectivity against creatinine and glucose. Using the SERS as signalling system, the spectra confirmed differentiated signals from the background within 0.025 ng/mL to 250 ng/mL of CEA. As expected, the Raman signal of the reporter increased with increasing CEA concentrations, and contributed to confirm the accuracy of the analytical data. Overall, this approach is simple, and may be adaptable to new multiplexing devices, also being adaptable to mass production.
TipoArtigo
URIhttps://hdl.handle.net/1822/68202
DOI10.1016/j.electacta.2020.137377
ISSN0013-4686
Versão da editorahttps://www.journals.elsevier.com/electrochimica-acta
Arbitragem científicayes
AcessoAcesso restrito UMinho
Aparece nas coleções:CEB - Publicações em Revistas/Séries Internacionais / Publications in International Journals/Series

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
document_53963_1.pdf
Acesso restrito!
2,99 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID