Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/68383

TítuloExperimental evaluation of out-of-plane strength of masonry walls retrofitted with oriented strand board
Autor(es)Iuorio, Ornella
Dauda, Jamiu A.
Lourenço, Paulo B.
Palavras-chaveDisplacement
Load capacity
Oriented strand board
Out-of-plane
Retrofit
Testing
Timber panel
Toughness
Unreinforced masonry wall
Data2021
EditoraElsevier
RevistaConstruction and Building Materials
Resumo(s)Structural retrofitting is carried out as an economical alternative to demolishing and rebuilding existing masonry structures. Retrofitting is provided to offer structural upgrade and damage-control. This paper presents the application of oriented strand board type 3 (OSB/3) for retrofitting unreinforced masonry walls. Out-of-plane bending test in form of four-point loading was performed on six masonry walls. The test results show that OSB/3 can considerably increase the load and flexure capacity by (1.4 & 1.8), limiting-toughness by (1.6 & 2.4) and overall-toughness by (16 & 10) times compared to plain wall subjected to out-of-plane loading for (single & double-sided) application respectively.
TipoArtigo
URIhttps://hdl.handle.net/1822/68383
DOI10.1016/j.conbuildmat.2020.121358
ISSN0950-0618
Versão da editorahttps://www.sciencedirect.com/science/article/pii/S0950061820333626
Arbitragem científicayes
AcessoAcesso restrito UMinho
Aparece nas coleções:ISISE - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Experimental_Evaluation_of_Out-of-Plane_Strength_of_Masonry_Walls.pdf
Acesso restrito!
2,46 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID