TítuloSustainable test cell : performance evaluation
Autor(es)Silva, Pedro Correia Pereira da
Bragança, L.
Mendonça, Paulo
Almeida, Manuela Guedes de
Palavras-chaveSustainable
Passive solar technologies
Test cell
Energy simulation
Data2006
CitaçãoFERNANDES, E. de Oliveira ; SILVA, M. Gameiro da ; PINTO, J. Rosado, eds. – “Healthy Buildings 2006 : proceedings of the Heathy Buildings : creating a heathy indoor environment for people, Lisboa, Portugal, 2006.” Lisboa : Instituto de Engenharia Mecânica, 2006. p. 247- 252.
Resumo(s)Energy is one of the main causes of the environmental pollution. In the European Union, buildings are responsible for 40% of the final energy demand and 1/3 of the emissions of greenhouse gases. Therefore, in order to promote the energy consumption reduction, it is fundamental to employ sustainable development principles in the construction sector. In order to demonstrate and show the potentialities of Sustainable building technologies two Test Cells were built. Comparing the solutions obtained via “in-situ” measurements and energy simulation tools, it was verified that the new Sustainable solution has a better energetic and environmental performance.
TipoArtigo em ata de conferência
URIhttps://hdl.handle.net/1822/7088
ISBN9789899506718
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:CEC-GTC - Comunicações a Conferências Internacionais