Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/71191

TítuloSemi-automatic aortic valve tract segmentation in 3D cardiac magnetic resonance images using shape-based B-spline Explicit Active Surfaces
Autor(es)Queirós, Sandro Filipe Monteiro
Morais, Pedro André Gonçalves
Fonseca, Jaime C.
D'hooge, Jan
Vilaça, João L.
Palavras-chaveAortic valve segmentation
Cardiac magnetic resonance
TAVI
Semi-automatic analysis
Data2019
EditoraSociety of Photo-optical Instrumentation Engineers (SPIE)
RevistaProceedings of SPIE
Resumo(s)Accurate preoperative sizing of the aortic annulus (AoA) is crucial to determine the best fitting prosthesis to be implanted during transcatheter aortic valve (AV) implantation (TAVI). Although multidetector row computed tomography is currently the standard imaging modality for such assessment, 3D cardiac magnetic resonance (CMR) is a feasible radiation-free alternative. However, automatic AV segmentation and sizing in 3D CMR images is so far underexplored. In this sense, this study proposes a novel semi-automatic algorithm for AV tract segmentation and sizing in 3D CMR images using the recently presented shape-based B-spline Explicit Active Surfaces (BEAS) framework. Upon initializing the AV tract surface using two user-defined points, a dual-stage shape-based BEAS evolution is performed to segment the patient-specific AV wall. The obtained surface is then aligned with multiple reference AV tract surfaces to estimate the location of the aortic annulus, allowing to extract the relevant clinical measurements. The framework was validated in thirty datasets from a publicly available CMR benchmark, assessing the segmentation accuracy and the measurements' agreement against manual sizing. The automated segmentation showed an average absolute distance error of 0.54 mm against manually delineated surfaces, while demonstrating to be robust against the algorithm's parameters. In its turn, automated AoA area-derived diameters showed an excellent agreement against manual-based ones (-0.30 +/- 0.77 mm), being comparable to the interobserver agreement. Overall, the proposed framework proved to be accurate, robust and computationally efficient (around 1 sec) for AV tract segmentation and sizing in 3D CMR images, thus showing its potential for preoperative TAVI planning.
TipoArtigo em ata de conferência
URIhttps://hdl.handle.net/1822/71191
ISBN9781510625457
DOI10.1117/12.2512777
ISSN0277-786X
Versão da editorahttps://www.spiedigitallibrary.org/conference-proceedings-of-spie/10949/2512777/Semi-automatic-aortic-valve-tract-segmentation-in-3D-cardiac-magnetic/10.1117/12.2512777.short
Arbitragem científicayes
AcessoAcesso restrito UMinho
Aparece nas coleções:DEI - Artigos em atas de congressos internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
SQueiros_SPIE_2019.pdf
Acesso restrito!
602,05 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID