Utilize este identificador para referenciar este registo:
https://hdl.handle.net/1822/14705
Registo completo
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Sepúlveda, A. T. | - |
dc.contributor.author | Fachin, F. | - |
dc.contributor.author | Guzmán de Villoria, R. | - |
dc.contributor.author | Wardle, B. L. | - |
dc.contributor.author | Viana, J. C. | - |
dc.contributor.author | Pontes, A. J. | - |
dc.contributor.author | Rocha, Luís A. | - |
dc.date.accessioned | 2011-11-30T15:01:13Z | - |
dc.date.available | 2011-11-30T15:01:13Z | - |
dc.date.issued | 2011 | - |
dc.date.submitted | 2011-06-17 | - |
dc.identifier.citation | Procedia Engineering 25 (2011) 140 – 143 | - |
dc.identifier.issn | 1877-7058 | por |
dc.identifier.uri | https://hdl.handle.net/1822/14705 | - |
dc.description.abstract | A new approach for the fabrication of flexible pressure sensors based on aligned carbon nanotubes (A-CNTs) is described in this paper. The technology is suitable for blood pressure sensors that can be attached to a stent-graft and deployed during an endovascular aneurysm repair (EVAR) procedure. Given the specifications of EVAR, the device should be foldable (extremely flexible) and characterized by a (very small) profile that integrates with the stent-graft cross section. A-CNTs embedded in a flexible substrate of polydimethylsiloxane (PDMS), a transparent, nontoxic and biocompatible silicone elastomer, are used to fabricate elements of the capacitive sensors. Fabricated prototypes validate our approach and show that CNTs/PDMS layered composites can be used to create highly flexible pressure sensors. | por |
dc.description.sponsorship | Fundação para a Ciência e a Tecnologia (FCT) - SFRH/BD/42922/2008, MIT-PT/EDAMEMD/0007/2008. | por |
dc.language.iso | eng | por |
dc.publisher | Elsevier 1 | por |
dc.relation | info:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBD%2F42922%2F2008/PT | - |
dc.relation | info:eu-repo/grantAgreement/FCT/5876-PPCDTI/83671/PT | - |
dc.rights | restrictedAccess | por |
dc.subject | Flexible pressure sensor | por |
dc.subject | Aneurysms | por |
dc.subject | Carbon nanotubes | por |
dc.subject | Pressure sensor design | por |
dc.subject | polymer nanocomposite | por |
dc.title | Nanocomposite flexible pressure sensor for biomedical applications | por |
dc.type | conferencePaper | - |
dc.peerreviewed | yes | por |
dc.relation.publisherversion | http://www.elsevier.com | por |
sdum.publicationstatus | published | por |
oaire.citationStartPage | 140 | por |
oaire.citationEndPage | 143 | por |
oaire.citationTitle | Procedia Engineering: Proc. Eurosensors XXV, September 4-7, 2011, Athens, Greece | por |
oaire.citationVolume | 25 | por |
dc.identifier.doi | 10.1016/j.proeng.2011.12.035 | por |
dc.subject.wos | Science & Technology | por |
sdum.journal | Procedia Engineering | por |
sdum.conferencePublication | EUROSENSORS XXV | por |
Aparece nas coleções: | IPC - Artigos em revistas científicas internacionais com arbitragem |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Eurosensors_2011_PaperFinalAlexandra.pdf Acesso restrito! | 199,35 kB | Adobe PDF | Ver/Abrir |