Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/27039

Registo completo
Campo DCValorIdioma
dc.contributor.authorDominguez-Godinez, Carmen Olalla-
dc.contributor.authorMartin-Gil, Alba-
dc.contributor.authorCarracedo, Gonzalo-
dc.contributor.authorGuzman-Aranguez, Ana-
dc.contributor.authorGonzález-Méijome, José Manuel-
dc.contributor.authorPintor, Jésus-
dc.date.accessioned2013-12-16T14:31:36Z-
dc.date.available2013-12-16T14:31:36Z-
dc.date.issued2013-
dc.identifier.issn1888-4296por
dc.identifier.urihttps://hdl.handle.net/1822/27039-
dc.description.abstractPurpose: To evaluate the possible use of soft contact lenses (CL) to improve the secretagogue role of diadenosine tetraphosphate (Ap4A) promoting tear secretion. Methods: Two conventional hydrogel CL (Omafilcon A and Ocufilcon D) and two silicone hydrogel (SiH) CL (Comfilcon A and Balafilcon A) were used. Ap4A was loaded into the lenses by soaking in a 1 mM Ap4A solution during 12 h. In vitro experiments were performed by placing the lenses in multi-wells during 2 h containing 1 ml of ultrapure water. 100 l aliquots were taken at time zero and every minute for the first 10 min, and then every 15 min. In vivo experiments were performed in New Zealand rabbits and both the dinucleotide release from SiH and tear secretion were measured by means of Schirmer strips and high-pressure liquid chromatography (HPLC) analysis. Results: Ap4A in vitro release experiments in hydrogel CL presented a release time 50 (RT50) of 3.9 ± 0.2 min and 3.1 ± 0.1 min for the non-ionic and the ionic CL, respectively. SiH CL released also Ap4A with RT50 values of 5.1 ± 0.1 min for the non-ionic and 2.7 ± 0.1 min for the ionic CL. In vivo experiments with SiH CL showed RT50 values of 9.3 ± 0.2 min and 8.5 ± 0.2 min for the non-ionic and the ionic respectively. The non-ionic lens Ap4A release was able to induce tear secretion above baseline tear levels for almost 360 min. Conclusion: The delivery of Ap4A is slower and the effect lasts longer with non-ionic lenses than ionic lenses.por
dc.description.sponsorship(undefined)por
dc.language.isoengpor
dc.publisherElsevier 1por
dc.rightsopenAccesspor
dc.subjectAp4Apor
dc.subjectDrug deliverypor
dc.subjectContact lensespor
dc.subjectAp A 4por
dc.titleIn vitro and in vivo delivery of the secretagogue diadenosine tetraphosphate from conventional and silicone hydrogel soft contact lensespor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttp://www.sciencedirect.com/science/journal/18884296por
oaire.citationStartPage205por
oaire.citationEndPage211por
oaire.citationIssue4por
oaire.citationTitleJournal of Optometrypor
oaire.citationVolume6por
dc.date.updated2013-12-14T01:58:02Z-
dc.identifier.doi10.1016/j.optom.2013.07.004por
sdum.journalJournal of Optometrypor
Aparece nas coleções:CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
5.6.45. DOMINGUEZ-GODINEZ_13_JOPTOM_(Diadenosine Delivery).pdf780,8 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID