Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/35033

Registo completo
Campo DCValorIdioma
dc.contributor.authorGarcía-Porta, Nerypor
dc.contributor.authorRico-del-Viejo, L.por
dc.contributor.authorNeves, Helenapor
dc.contributor.authorMatos, Sofia Cláudia Peixoto depor
dc.contributor.authorQueirós, A.por
dc.contributor.authorGonzález-Méijome, José Manuelpor
dc.date.accessioned2015-05-04T14:18:02Z-
dc.date.available2015-05-04T14:18:02Z-
dc.date.issued2015-
dc.identifier.citationGarcía-Porta, Nery; Rico-del-Viejo, Laura; Neves, Helena; Peixoto-de-Matos, Sofia Claudia; Queirós, António; González-Méijome JM. Performance of Three Multipurpose Disinfecting Solutions with a Silicone Hydrogel Contact Lens, BioMed Research International , 216932, 1, 1-13, 2015.por
dc.identifier.issn2314-6133por
dc.identifier.issn2314-6141por
dc.identifier.urihttps://hdl.handle.net/1822/35033-
dc.description"Article ID 216932"por
dc.description.abstractTo evaluate the clinical performance of a silicone hydrogel (Si-Hy) soft contact lens (CL) in combination with three differentmultipurpose disinfecting solutions (MPDSs).Methods.Thiswas a prospective, randomized, single-masked, crossover, and comparative study in which 31 habitual soft CL wearers were randomly assigned to one of the three MPDSs (Synergi, COMPLETE RevitaLens, and OPTI-FREE PureMoist) for 1 month with a 1-week wash-out period between each exposure. All subjects were successfully refitted with a Si-Hy CL (Biofinity). Subjects were then scheduled for follow-up visits after 1 month of lens wear, being evaluated at 2 and 8 hours after lens insertion. Visual Analogue Scales (VAS) were used to gauge comfort rating. Results. The tarsal conjunctiva showed a significantly different degree of lid redness between the MPDSs at the 2-hour visit (P < 0.05, Kruskal- Wallis test), being lower for COMPLETE RevitaLens compared to the other two MPDSs (Mann-Whitney U test). Furthermore, a significantly different degree of lid roughness at the 8-hour visit was seen (P < 0.05, Kruskal-Wallis test), being higher for Synergi (Mann-Whitney U test).Thesubjective comfort was similar with the threeMPDSs. Conclusion. Tarsal conjunctival response should be also considered in the context of the clinical performance of MPDs at the ocular surface.-
dc.description.sponsorshipThis work has been funded by an unrestricted grant from AMO Germany GmbH and it was also partially supported by Xunta de Galicia, Spain (Predoctoral Grant) and Fundacao para a Ciencia e Tecnologia, Portugal.por
dc.language.isoengpor
dc.publisherHindawi Publishing Corporationpor
dc.rightsopenAccesspor
dc.titlePerformance of three multipurpose disinfecting solutions with a silicone hydrogel contact lenspor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttp://dx.doi.org/10.1155/2015/216932por
sdum.publicationstatuspublishedpor
oaire.citationStartPage1por
oaire.citationEndPage13por
oaire.citationTitleBioMed research internationalpor
oaire.citationVolume2015por
dc.date.updated2015-04-30T14:51:42Z-
dc.identifier.doi10.1155/2015/216932-
dc.identifier.pmid25918703por
dc.subject.wosScience & Technologypor
sdum.journalBioMed research internationalpor
Aparece nas coleções:CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
GARCIA-PORTA_2105 (Performance of Three Multipurpose Disinfecting Solutions with a Silicone Hydrogel CL).pdf2,11 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID