dc.description.abstractIn spite of all innovations in stent design, commonly used metallic stents present several problems such as corrosion, infection and restenosis, leading to health complications or even death of patients. In this context, the present paper reports a systematic investigation on designing and development of 100% fiber based stents, which can eliminate or minimize the problems with existing metallic stents. For this purpose, braided stents were produced by varying different materials, structural and process parameters such as mono-filament type and diameter, braiding angle and mandrel diameter. The influence of these design parameters on mechanical behavior as well as stent's porosity was thoroughly investigated, and suitable parameters were selected for developing a stentwith mechanical characteristics and porosity matching with the commercial stents. According to the experimental results, the best performance was achieved with a polyester stent designed with 0.27 mm monofilament diameter, braiding angle of 35° and mandrel diameter of 6 mm, providing similar properties to commercial Nitinol stents.por
dc.description.sponsorshipThis project is supported by Portuguese Foundation for Science and Technology (FCT) through the PhD grant SFRH/BD/90321/2012.por
dc.language.isoengpor
dc.publisherElsevier 1por
dc.relationThis project is supported by Portuguese Foundation for Science and Technology (FCT) through the PhD grant SFRH/BD/90321/2012.por
dc.rightsrestrictedAccesspor
dc.subjectFibrous stentspor
dc.subjectBraidingpor
dc.subjectDesign parameterspor
dc.subjectMechanical behaviorpor
dc.subjectPorositypor
dc.titleInfluence of design parameters on the mechanical behavior and porosity of braided fibrous stentspor
dc.typearticlepor
dc.peerreviewedyespor
sdum.publicationstatuspublishedpor
oaire.citationStartPage237por
oaire.citationEndPage247por
oaire.citationTitleJournal Materials and Designpor
oaire.citationVolume86por
dc.identifier.doi10.1016/j.matdes.2015.07.051por
dc.subject.wosScience & Technologypor
sdum.journalJournal Materials and Designpor
Aparece nas coleções:CDF - GRF - Artigos/Papers (with refereeing)
DET/2C2T - Artigos em revistas internacionais com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
x5_2015 Influence of Design Parameters on the Mechanical Behavior and Porosity of Braided Fibrous Stents.pdf
Acesso restrito!
2,87 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID