Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/40227

TítuloAccuracy comparison of implant impression techniques: A systematic review
Autor(es)Moreira, António Herculano Jesus
Rodrigues, Nuno F.
Pinho, A. C. Marques de
Fonseca, Jaime C.
Vilaça, João L.
Palavras-chaveImplant impression
Implant misfit
Impression accuracy
Optical scanning
Dental prosthesis
DataOut-2015
EditoraWiley
RevistaClinical Implant Dentistry and Related Research
CitaçãoMoreira, A. H., Rodrigues, N. F., Pinho, A., Fonseca, J. C., & Vilaça, J. L. (2015). Accuracy Comparison of Implant Impression Techniques: A Systematic Review. Clinical implant dentistry and related research, 17(S2), e751-e764
Moreira, A. H. J., Rodrigues, N. F., Pinho, A. C. M., Fonseca, J. C., & Vilaca, J. L. (2015). Accuracy Comparison of Implant Impression Techniques: A Systematic Review. Clinical Implant Dentistry and Related Research, 17, E751-E764. doi: 10.1111/cid.12310
Resumo(s)Background Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose To identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles was identified, 32 were selected for review. Results All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in 9; 6 studies tested vinyl polysiloane and 1 study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intra-oral optical devices were compared in 4 studies. Conclusions The most accurate results were achieved with two configurations: (1) the optical intra-oral system with powder; and (2) the open technique with splinted squared transfer copings, using polyether as impression material.
TipoArtigo
URIhttps://hdl.handle.net/1822/40227
DOI10.1111/cid.12310
ISSN1523-0899
1708-8208
Versão da editorahttp://onlinelibrary.wiley.com/doi/10.1111/cid.12310/full
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:ICVS - Artigos em revistas internacionais / Papers in international journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
moreira_et_al-2015-clinical_implant_dentistry_and_related_research.pdf143,62 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID