Utilize este identificador para referenciar este registo:
https://hdl.handle.net/1822/47570
Registo completo
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Coelho-Marín, Gustavo | por |
dc.contributor.author | Castanheira, Elisabete M. S. | por |
dc.contributor.author | Queirós, A. | por |
dc.contributor.author | Lira, Madalena | por |
dc.date.accessioned | 2017-11-20T13:41:09Z | - |
dc.date.issued | 2017-04 | - |
dc.identifier.uri | https://hdl.handle.net/1822/47570 | - |
dc.description.abstract | Aim: To evaluate the variation in transmittance in the UV-visible spectrum (230 nm 700 nm) between different batches of contact lenses (CL). Methods: Five monthly and five daily CL were studied. For each brand and power ( 3.00D), three different batches were analyzed. Transmittance (%T) was measured in the visible and ultraviolet spectral region, using a Shimadzu UV 3101 PC spectrophotometer equipped with an integrating sphere. Results: Visible Region (400–700 nm): The average values of %T for monthly lenses varied between 91.31±2.64 and 95.83±1.35. It was verified a statistically significant difference between batches (p<0.05) for all lenses. Regarding daily lenses, the average values of %T ranged between 91.90±1.63 and 96.09±3.00. A statistically significant difference between batches was also found for all lenses (p<0.001). UVA Region (315–400 nm): The average values of %T for monthly lenses varied between 20.31±32.32 and 93.58±1.89. In daily lenses, the values ranged between 18.70±30.52 and 92.32±3.43. For both types, some CL showed statistically significant differences between batches (p<0.05). UVB Region (280–315 nm): The average values of %T for monthly lenses varied between 0.02±0.07 and 91.23±1.88. For daily CL varied between 0.01±0.03 and 79.84±6.80. In this region, some CL also showed statistically significant differences between batches (p < 0.05). UVC Region (230–280 nm): The average values of %T for monthly lenses ranged between 3.29±0.07 and 53.69±35.65. For daily CL varied between 1.35±12.06 and 40.09±23.70. In this region, no statistically significant differences between batches were observed. Conclusion: There are changes in transmittance values between different batches, more pronounced in some regions of UV-Visible spectrum. In the visible region, all lenses differ significantly in their transmittance, but the differences obtained may have no impact on visual performance. | por |
dc.language.iso | eng | por |
dc.rights | restrictedAccess | por |
dc.title | Evaluation of transmittance changes between different batches of contact lenses | por |
dc.type | conferencePoster | por |
dc.peerreviewed | yes | por |
oaire.citationConferenceDate | 22 - 23 abril 2017 | por |
sdum.event.title | Congresso Internacional de Optometria e Ciências da Visão | por |
sdum.event.type | congress | por |
oaire.citationConferencePlace | Universidade de Minho, Braga, Portugal | por |
dc.subject.fos | Ciências Médicas::Ciências da Saúde | por |
dc.description.publicationversion | info:eu-repo/semantics/publishedVersion | por |
Aparece nas coleções: | CDF - OCV - Comunicações/Communications (with refereeing) |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Resumo_CIOCV-Final.pdf Acesso restrito! | 350,75 kB | Adobe PDF | Ver/Abrir |