Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/49692

Registo completo
Campo DCValorIdioma
dc.contributor.authorQueirós, Sandro Filipe Monteiropor
dc.contributor.authorDubois, Christophepor
dc.contributor.authorMorais, Pedro André Gonçalvespor
dc.contributor.authorAdriaenssens, Tompor
dc.contributor.authorFonseca, Jaime C.por
dc.contributor.authorVilaça, João L.por
dc.contributor.authorD'hooge, Janpor
dc.date.accessioned2018-01-25T11:26:39Z-
dc.date.available2018-01-25T11:26:39Z-
dc.date.issued2017-01-17-
dc.identifier.citationQueirós, S., Dubois, C., Morais, P., Adriaenssens, T., et. al. (2017). Automatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantation. Journal of cardiovascular computed tomography, 11(1), 25-32por
dc.identifier.issn1934-5925-
dc.identifier.urihttps://hdl.handle.net/1822/49692-
dc.description.abstractBackground: Accurate imaging assessment of aortic annulus (AoA) dimension is paramount to decide on the correct transcatheter heart valve (THV) size for patients undergoing transcatheter aortic valve implantation (TAVI). We evaluated the feasibility and accuracy of a novel automatic framework for multi detector row computed tomography (MDCT)-based TAVI planning. Methods: Among 122 consecutive patients undergoing TAVI and retrospectively reviewed for this study, 104 patients with preoperative MDCT of sufficient quality were enrolled and analyzed with the proposed software. Fully automatic (FA) and semi-automatic (SA) AoA measurements were compared to manual measurements, with both automated and manual-based interobserver variability (IOV) being assessed. Finally, the effect of these measures on hypothetically selected THV size was evaluated against the implanted size, as well as with respect to manually-derived sizes. Results: FA analysis was feasible in 92.3% of the cases, increasing to 100% if using the SA approach. Automatically-extracted measurements showed excellent agreement with manually-derived ones, with small biases and narrow limits of agreement, and comparable to the interobserver agreement. The SA approach presented a statistically lower IOV than manual analysis, showing the potential to reduce interobserver sizing disagreements. Moreover, the automated approaches displayed close agreement with the implanted sizes, similar to the ones obtained by the experts. Conclusion: The proposed automatic framework provides an accurate and robust tool for AoA measurements and THV sizing in patients undergoing TAVI.por
dc.description.sponsorshipFCT - Fundação para a Ciência e a Tecnologia, Portugal, and the European Social Found, European Union, through the Programa Operacional Capital Humano (POCH) in the scope of the PhD grants SFRH/BD/93443/2013 (S. Queirós) and SFRH/BD/95438/2013 (P. Morais), and the project ‘PersonalizedNOS (01-0145-FEDER-000013)’ co-funded by Programa Operacional Regional do Norte (QREN), through Fundo Europeu de Desenvolvimento Regional (FEDER)por
dc.language.isoengpor
dc.publisherElsevier 1por
dc.rightsopenAccesspor
dc.subjectComputed tomographypor
dc.subjectTAVIpor
dc.subjectAortic valve sizingpor
dc.subjectFully automatic analysispor
dc.subjectSemi-automatic analysispor
dc.titleAutomatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantationpor
dc.typearticlepor
dc.peerreviewedyespor
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S1934592516302908por
oaire.citationStartPage25por
oaire.citationEndPage32por
oaire.citationIssue1por
oaire.citationVolume11por
dc.date.updated2018-01-08T14:39:28Z-
dc.identifier.doi10.1016/j.jcct.2016.12.004por
dc.identifier.pmid28063844por
dc.subject.fosCiências Médicas::Medicina Básicapor
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.subject.wosScience & Technologypor
sdum.journalJournal of Cardiovascular Computed Tomographypor
Aparece nas coleções:ICVS - Artigos em revistas internacionais / Papers in international journals
DEI - Artigos em revistas internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
63.pdf1,76 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID