Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/52768

Registo completo
Campo DCValorIdioma
dc.contributor.authorde Castro, Saul Matospor
dc.contributor.authorMoreira, Ruipor
dc.contributor.authorBraga, A. C.por
dc.contributor.authorFerreira, Afonso Pinhaopor
dc.contributor.authorPollmann, Maria Cristinapor
dc.date.accessioned2018-03-19T11:36:26Z-
dc.date.available2018-03-19T11:36:26Z-
dc.date.issued2015-07-01-
dc.identifier.issn2234-7518-
dc.identifier.urihttps://hdl.handle.net/1822/52768-
dc.description.abstractObjective: To quantify, for each activation, the effect of preactivations of differing distribution and intensity on the neutral position of T-loops (7-mm height), specifically the horizontal force, moment to force (M/F) ratio, and load to deflection ratio. Methods: A total 100 loops measuring 0.017 x 0.025 inches in cross-section were divided into two groups (n = 50 each) according to composition, either stainless steel or beta-titanium. The two groups were further divided into five subgroups, 10 loops each, corresponding to the five preactivations tested: preactivations with occlusal distribution (00, 200, and 401, gingival distribution (201, and occlusal-gingival distribution (40). The loops were subjected to a total activation of 6-mm with 0.5-mm iterations. Statistical analysis was performed using comprised ANOVA and Bonferoni multiple comparison tests, with a significance level of 5%. Results: The location and intensity of preactivation influenced the force intensity. For the M/F ratio, the highest value achieved without preactivation was lower than the height of the loop. Without preactivation, the M/F ratio increased with activation, while the opposite effect was observed with preactivation. The increase in the M/F ratio was greater when the preactivation distribution was partially or fully gingival. Conclusions: Depending on the preactivation distribution, displacement of uprights is higher or lower than the activation, which is a factor to consider in clinical practice.por
dc.description.sponsorshipThis study was carried out and financed by the Faculty of Dental Medicine of University of Porto.por
dc.language.isoengpor
dc.publisherKorean Association of Orthodontistspor
dc.rightsopenAccesspor
dc.subjectNeutral positionpor
dc.subjectPreactivationpor
dc.subjectT-looppor
dc.titleEffect of activation and preactivation on the mechanical behavior and neutral position of stainless steel and beta-titanium T-loopspor
dc.typearticlepor
dc.peerreviewedyespor
oaire.citationStartPage198por
oaire.citationEndPage208por
oaire.citationIssue4por
oaire.citationVolume45por
dc.date.updated2018-03-14T16:43:39Z-
dc.identifier.doi10.4041/kjod.2015.45.4.198por
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.subject.wosScience & Technology-
sdum.export.identifier4508-
sdum.journalKorean Journal of Orthodonticspor
Aparece nas coleções:CAlg - Artigos em revistas internacionais / Papers in international journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
RevInd3_2015_KJO14_Saul.pdf976,3 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID