Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/52778

Registo completo
Campo DCValorIdioma
dc.contributor.authorSilva, Antonio Sergiopor
dc.contributor.authorAroso, Carlospor
dc.contributor.authorUstrell, Raulpor
dc.contributor.authorBraga, A. C.por
dc.contributor.authorMendes, Jose Manuelpor
dc.contributor.authorEscuin, Tomaspor
dc.date.accessioned2018-03-19T11:53:35Z-
dc.date.available2018-03-19T11:53:35Z-
dc.date.issued2015-
dc.identifier.issn2005-7806-
dc.identifier.urihttps://hdl.handle.net/1822/52778-
dc.description.abstractThe aim of this study was to compare the durability and retention of 4 types of attachments placed over computer aided design/computer aided manufacturing (CAD/CAM) titanium bars when subjected to different pH conditions. MATERIALS AND METHODS. Four commercially available attachments were investigated: Hader Yellow, Hader Red, Ackerman Gold and Ackerman Stainless Steel. These attachments and Ackerman CAD/CAM titanium bars were placed in 2 vessels containing different artificial saliva solutions (pH 7/ pH 4) at 37 degrees C for one month to simulate corrosion conditions, and they were then subjected to mechanical testing (5400 cycles of insertion and removal). RESULTS. The results revealed that there were significant differences in the average values of insertion/removal force due to the pH (F (1, 24)=9.207, P<9.05) and the type of attachment (F (3, 24)=11.742, P<.05). CONCLUSION. More acidic pH values were found to have a negative influence on the retention capacity of the attachments.por
dc.language.isoengpor
dc.publisherThe Korean Academy of Prosthodonticspor
dc.rightsopenAccesspor
dc.subjectDental implantspor
dc.subjectEdentulous patientspor
dc.subjectOverdenturespor
dc.subjectAttachmentspor
dc.subjectCorrosionpor
dc.titleThe influence of saliva pH value on the retention and durability of bar-clip attachmentspor
dc.typearticlepor
dc.peerreviewedyespor
oaire.citationStartPage32por
oaire.citationEndPage38por
oaire.citationIssue1por
oaire.citationVolume7por
dc.date.updated2018-03-14T17:16:27Z-
dc.identifier.doi10.4047/jap.2015.7.1.32por
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.subject.wosScience & Technology-
sdum.export.identifier4516-
sdum.journalJournal of Advanced Prosthodonticspor
Aparece nas coleções:CAlg - Artigos em revistas internacionais / Papers in international journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
RevInd7_2015_jap-7-32_SergioSilva.pdf2,07 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID