Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/53308

TítuloExperimental assessment of Emitted Dose from Valved Holding Chamber devices
Autor(es)Oliveira, Ricardo Falcão
Silva, Manuel Viana
Machado, A. V.
Oliveira, Manuel António Sousa Cortez Gonçalves
Marques, Helena Maria Cabral
Teixeira, S. F. C. F.
Teixeira, J. Carlos
Palavras-chaveValved Holding Chamber (VHC)
Emitted Dose
Asthma
Data2015
EditoraAmerican Society of Mechanical Engineers (ASME)
Resumo(s)Due to the increasing worldwide incidence of asthma, a growing usage of inhalation devices has been observed. Some of the pressurized Metered Dose Inhalers (pMDI) limitations have been overcome by the introduction of newly and improved Valved Holding Chambers (VHC), resulting in good patient acceptance.The efficiency is assessed by the VHC Emitted Dose (ED), i.e. the amount of drug available to the patient.Using the pMDI salbutamol sulfate formulation (Ventolin (R) HFA-134a) as the test drug, several VHC devices were assessed. These latest were grouped by material characteristics: dissipative (OptiChamber Diamond (R), AeroChamber Plus (R), Vortex (R), A2A Spacer (R)), non -dissipative (SpaceChamber Plus (R), Compact SpaceChamber Plus (R), Volumatic (R)) and stainless steel (Nebuchamber (R)).The pMDI + VHC were assembled to a filter housing, which comprises an induction port with similar USP Throat dimensions, and connected to a vacuum pump (calibrated at 15, 26 and 40 L/min). Using UV-Vis Spectrophotometry equipment at 244 nm, it was possible to determine its concentration for later mass calculation. For all the VHC devices tested, the total mass recovery percentage was between 85% and 120%.At 26 L/min, the Vortex (R) VHC has shown the highest ED (47.3 +/- 1.8 %).The ED may not be dependent on the volume of the VHC. Although, further analysis of the results suggests the existence of a linear correlation between the ED and the VHC body length.SpaceChamber Plus (R) results show an increase of the ED and, subsequently, a decrease in VHC deposition fraction, with the increase of airflow.
TipoArtigo em ata de conferência
URIhttps://hdl.handle.net/1822/53308
ISBN9780791846469
DOI10.1115/IMECE201438846
Arbitragem científicayes
AcessoAcesso restrito autor
Aparece nas coleções:CAlg - Artigos em livros de atas/Papers in proceedings
IPC - Textos completos em actas de encontros científicos internacionais com arbitragem

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
10.1115@IMECE2014-38846.pdf
Acesso restrito!
319,46 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID