Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/55737

Registo completo
Campo DCValorIdioma
dc.contributor.authorRibeiro, S.por
dc.contributor.authorGomes, Andreia Cpor
dc.contributor.authorEtxebarria, I.por
dc.contributor.authorLanceros-Méndez, S.por
dc.contributor.authorRibeiro, Clarissepor
dc.date.accessioned2018-09-04T22:26:00Z-
dc.date.issued2018-11-
dc.identifier.citationRibeiro, S.; Gomes, A. C.; Etxebarria, I.; Lanceros-Méndez, S.; Ribeiro, Clarisse, Electroactive biomaterial surface engineering effects on muscle cells differentiation. Materials Science and Engineering C, 92, 868-874, 2018por
dc.identifier.issn0928-4931por
dc.identifier.urihttps://hdl.handle.net/1822/55737-
dc.description.abstractEven though skeletal muscle cells can naturally regenerate as a response to insignificant tissue damages, more severe injuries can cause irreversible loss of muscle cells mass and/or function. Until now, cell therapies are not a good approach to treat those injuries. Biomaterials such as poly(vinylidene fluoride), PVDF, can improve muscle regeneration by presenting physical cues to muscle cells that mimic the natural regeneration environment. In this way, the ferroelectric and piezoelectric properties of PVDF offer new opportunities for skeletal muscle tissue engineering once the piezoelectricity is an electromechanical effect that can be used to provide electrical signals to the cells, upon mechanical solicitations, similar to the ones found in several body tissues. Thus, previous to dynamic experiments, it is important to determine how the surface properties of the material, both in terms of the poling state (positive or negative net surface charge) and of the morphology (films or fibers) influence myoblast differentiation. It was observed that PVDF promotes myogenic differentiation of C2C12 cells as evidenced by quantitative analysis of myotube fusion, maturation index, length, diameter and number. Charged surfaces improve the fusion of muscle cells into differentiated myotubes, as demonstrated by fusion and maturation index values higher than the control samples. Finally, the use of random and oriented -PVDF electrospun fibers scaffolds has revealed differences in cell morphology. Contrary to the randomly oriented fibers, oriented PVDF electrospun fibers have promoted the alignment of the cells. It is thus demonstrated that the use of this electroactive polymer represents a suitable approach for the development of electroactive microenvironments for effective muscle tissue engineering.por
dc.description.sponsorshipThiswork was supported by thePortuguese Science and Technology Foundation (FCT) in the framework of the Strategic Funding UID/FIS/ 04650/2013 and UID/BIA/04050/2013 (POCI-01-0145-FEDER007569) and project POCI-01-0145-FEDER-028237 funded by national funds through Fundação para a Ciência e a Tecnologia (FCT) and by the ERDF through the COMPETE2020 - Programa Operacional Competitividade e Internacionalização (POCI). The authors also thank the FCT for the SFRH/BD/111478/2015 (S.R.) and SFRH/BPD/90870/ 2012 (C.R.) grants. The authors acknowledge funding by the Spanish Ministry of Economy and Competitiveness (MINECO) through the project MAT2016-76039-C4-3-R (AEI/FEDER, UE) and from the Basque Government Industry Department under the ELKARTEK program.por
dc.language.isoengpor
dc.publisherElsevier 1por
dc.relationinfo:eu-repo/grantAgreement/FCT/5876/147414/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/5876/147364/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/POR_NORTE/SFRH%2FBD%2F111478%2F2015/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBPD%2F90870%2F2012/PTpor
dc.rightsrestrictedAccesspor
dc.subjectTissue engineeringpor
dc.subjectPVDFpor
dc.subjectPiezoelectricpor
dc.subjectDifferentiationpor
dc.subjectMyoblast cellspor
dc.titleElectroactive biomaterial surface engineering effects on muscle cells differentiationpor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttps://www.journals.elsevier.com/materials-science-and-engineering-cpor
dc.commentsCEB47835por
oaire.citationStartPage868por
oaire.citationEndPage874por
oaire.citationVolume92por
dc.date.updated2018-09-04T16:56:26Z-
dc.identifier.eissn0928-4931por
dc.identifier.doi10.1016/j.msec.2018.07.044por
dc.identifier.pmid30184816por
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.subject.wosScience & Technologypor
sdum.journalMaterials Science and Engineering: Cpor
Aparece nas coleções:CEB - Publicações em Revistas/Séries Internacionais / Publications in International Journals/Series
CBMA - Artigos/Papers
CDF - FCD - Artigos/Papers (with refereeing)
DBio - Artigos/Papers

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
document_47835_1.pdf
Acesso restrito!
2,43 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID