Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/57075

Registo completo
Campo DCValorIdioma
dc.contributor.authorGonzález-Pérez, Javierpor
dc.contributor.authorQueiruga Piñeiro, Juanpor
dc.contributor.authorSánchez García, Ángelpor
dc.contributor.authorGonzález Méijome, José Manuelpor
dc.date.accessioned2018-11-26T10:33:14Z-
dc.date.available2018-11-26T10:33:14Z-
dc.date.issued2018-04-
dc.date.submitted2018-01-
dc.identifier.citationGonzález-Pérez, Javier; Queiruga Piñeiro, Juan; Sánchez García, Ángel; González Méijome, José Manuel. Comparison of Central Corneal Thickness Measured by Standard Ultrasound Pachymetry, Corneal Topography, Tono-Pachymetry and Anterior Segment Optical Coherence Tomography, Current Eye Research, 43, 7, 866-872, 2018.por
dc.identifier.issn0271-3683por
dc.identifier.urihttps://hdl.handle.net/1822/57075-
dc.description.abstractPurpose: To compare central corneal thickness (CCT) measured by standard ultrasound pachymetry (USP), and three non-contact devices in healthy eyes. Methods: A cross-sectional study of CCT measurement in 52 eyes of 52 healthy volunteers was done by a single examiner at Ocular Surface and Contact Lens Laboratory. Three consecutive measurements were done by standard USP, non-contact tono-pachymeter, Pentacam corneal topographer, and Anterior Segment Optical Coherence Tomography (AS-OCT). The mean values were used for assessment. The results were compared using multivariate ANOVA, linear regression, and Pearson correlation. Agreement among the devices was analyzed using mean differences and Bland–Altman analysis with 95% limits of agreement (LoA). Finally, reliability was analyzed using intraclass correlation coefficient (ICC). Results: Mean CCT by ultrasound pachymeter, tono-pachymeter, corneal topographer and AS-OCT were 558.9 ± 31.2 µm, 525.8 ± 43.1 µm, 550.4 ± 30.5 µm, and 545.9 ± 30.5 µm respectively. There was a significant positive correlation between AS-OCT and USP (Pearson correlation = 0.957, p < 0.001), corneal topography and USP (Pearson correlation = 0.965, p < 0.001), and corneal topography and AS-OCT (Pearson correlation = 0.965, p < 0.001). There was a lower correlation between CT-1P tono-pachymeter and the other three modalities. Intraclass correlation coefficients show an excellent reliability between pairs except for CT-1P against the other three instruments that were found moderate. Conclusions: CT-1P tono-pachymeter underestimates CCT measurements compared to Scheimpflug system, AS-OCT device, and USP. Mean CCT among USP, Pentacam and AS-OCT were comparable and had significant linear correlations. In clinical practice, these three modalities could be interchangeable in healthy patientspor
dc.language.isoengpor
dc.publisherTaylor and Francispor
dc.rightsopenAccesspor
dc.subjectCentral corneal thicknesspor
dc.subjectUltrasound pachymetrypor
dc.subjectNon-contact tono-pachymetrypor
dc.subjectScheimpflug camerapor
dc.subjectAnterior segment optical coherence tomographypor
dc.subjectInterchangeabilitypor
dc.titleComparison of central corneal thickness measured by standard ultrasound pachymetry, corneal topography, tono-pachymetry and anterior segment optical coherence tomographypor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttps://www.tandfonline.com/doi/abs/10.1080/02713683.2018.1461910por
oaire.citationStartPage866por
oaire.citationEndPage872por
oaire.citationIssue7por
oaire.citationVolume43por
dc.date.updated2018-11-23T18:41:12Z-
dc.identifier.eissn1460-2202por
dc.identifier.doi10.1080/02713683.2018.1461910por
dc.identifier.pmid29634372por
dc.subject.fosCiências Naturais::Ciências Físicaspor
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.subject.wosScience & Technologypor
sdum.journalCurrent Eye Researchpor
Aparece nas coleções:ASSESSMENT AND ENHANCING VISUAL PERFORMANCE (2018 - ...)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
5.5.135. GONZALEZ-PEREZ_18_CER (Pachometer Comparison).pdf1,19 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID