Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/67968

Registo completo
Campo DCValorIdioma
dc.contributor.authorRocha, J. G.por
dc.contributor.authorCorreia, V.por
dc.contributor.authorMartins, Marcos Silvapor
dc.contributor.authorCabral, Josépor
dc.date.accessioned2020-11-02T15:56:37Z-
dc.date.available2020-11-02T15:56:37Z-
dc.date.issued2013-
dc.identifier.urihttps://hdl.handle.net/1822/67968-
dc.description.abstractThis article describes a complete prototype system that can be used in electrotherapy treatments, that is, in medical treatments involving electric currents. The system is composed of two main blocks: the master and the slave. The Master block, whose main component is a CPU, controls the user interface. The Slave block, which is composed of a microcontroller and a wave generator, produces the appropriated voltages and currents compatible with the desired treatment. The whole system is powered by a 12 V power supply and the output signal voltage ranges between -100 V and 100 V. Despite the prototype being able of performing all the electrotherapy treatments in the low-medium frequency ranges, it was tested in aesthetic mesotherapy, namely in anticellulite, located anticellulite, antistretch, and antiflaccidity. In these treatments, the output signal is composed of an overlap of two frequencies: the first one is selected in the range of 1.2 kHz - 1.8 kHz and the second in the range of 0.07 Hz - 2 Hz. The system was tested in a clinical environment with real patients. It showed good results both in effectiveness of treatments and in terms of pain suffered by the patients.por
dc.description.sponsorship(undefined)por
dc.language.isoengpor
dc.publisherBentham Science Publisherspor
dc.rightsopenAccesspor
dc.subjectElectrotherapypor
dc.subjectMesotherapypor
dc.titleDesign and development of a prototype electrotherapy devicepor
dc.typearticlepor
dc.peerreviewedyespor
dc.relation.publisherversionhttps://openbiomedicalengineeringjournal.com/VOLUME/7/PAGE/100/por
oaire.citationStartPage100por
oaire.citationEndPage108por
oaire.citationIssue1por
oaire.citationVolume7por
dc.identifier.doi10.2174/1874120701307010100por
dc.subject.fosEngenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informáticapor
sdum.journalOpen Biomedical Engineering Journalpor
oaire.versionVoRpor
Aparece nas coleções:CAlg - Artigos em revistas internacionais / Papers in international journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
TOBEJ-7-100.pdf355,23 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID