TítuloChanges in light disturbance analyzer evaluation in SMILE for high myopia and astigmatism
Autor(es)Reinstein, Dan Z.
Archer, Timothy J.
González-Méijome, José Manuel
Vida, Ryan S.
Gupta, Ruchi
Data19-Out-2022
EditoraSlack Inc.
RevistaJournal of Refractive Surgery
CitaçãoReinstein, D. Z., Archer, T. J., González-Méijome, J. M., Vida, R. S., & Gupta, R. (2022, November). Changes in Light Disturbance Analyzer Evaluation in SMILE for High Myopia and Astigmatism. Journal of Refractive Surgery. SLACK, Inc. http://doi.org/10.3928/1081597x-20221019-02
Resumo(s)PURPOSE: To study the objective change in light distur- bance around a glare source using the Light Disturbance Analyzer (LDA) (Binarytarget Lda) and correlate this with the validated subjective quality of vision (QoV) question- naire in small incision lenticule extraction (SMILE) for high compound myopic astigmatism. METHODS: This was a prospective study recruiting 114 pa- tients undergoing SMILE with attempted spherical equivalent refraction (SEQ) correction from-9.00 to-13.00 diopters (D), and cylinder up to 5.00 D. The LDA was used before and 3 and 12 months after surgery to evaluate the Light Disturbance Area, Light Disturbance Index, Best Fit Circle Radius, and Best Fit Circle Irregularity. Patients completed the Raschvalidated QoV questionnaire before and 12 months after sur- gery. Correlation analysis was performed between the LDA parameters and the QoV frequency, severity, and bother- someness for halos and starbursts.RESULTS: At 12 months, there was a non-statistically signif- cant change of 11.9% for Light Disturbance Area and Light Dis- turbance Index and 6.5% for Best Fit Circle Radius. There was an increase of 81.9% for Best Fit Circle Irregularity (P = .017). Light Disturbance Area, Light Disturbance Index, and Best Fit Circle Radius correlated with bothersomeness for QoV halos, and with frequency, severity and bothersomeness for QoV star -bursts (P < .05), albeit with a low correlation coefficient (R2 < 0.13). There was no correlation between increase in Best Fit Circle Irregularity and the halo and starburst scores from the QoV questionnaire.CONCLUSIONS: LDA Best Fit Circle Irregularity was found to in- crease following high myopic SMILE. Other LDA parameters ap- peared to increase, but a much larger sample would be required to find statistical significance. The change in LDA parameters was only weakly correlated with QoV halo and starburst metrics, representing the wide variation in inter-subject perception.
TipoArtigo
URIhttps://hdl.handle.net/1822/85924
DOI10.3928/1081597X-20221019-02
ISSN1081-597X
Versão da editorahttps://journals.healio.com/doi/10.3928/1081597X-20221019-02
Arbitragem científicayes
AcessoAcesso restrito UMinho
Aparece nas coleções:ASSESSMENT AND ENHANCING VISUAL PERFORMANCE (2018 - ...)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
5.5.179. REINSTEIN_22_JRS JRS1122REINSTEIN.pdf
Acesso restrito!
3,19 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID