dc.description.abstractThe main objective of this article is to describe the development of a fully-integrated disposable lab-on-achip for point of care testing and monitoring of biochemical parameters in biological fluids. The lab-on-achip is composed mainly by two dies: the fluid and the detection. The fluid die, fabricated in SU-8, comprises three microfluidic cuvettes, containing the fluids into analysis, and a β-PVDF microagitation system. The detection die is fabricated in a CMOS standard process and contains the photodetectors and the electronics for signal actuation and detection. The main innovation of this lab-on-a-chip is the application of an acoustic microagitation technique by the deposition of the β-PVDF piezoelectric polymer underneath the microfluidic structures, with automatic electronic control. This piezoelectric polymer produces mechanical vibrations, which allow the enhancement of the mixing and the reaction.en
dc.description.sponsorshipFundação para a Ciência e a Tecnologia (FCT) - PTDC/BIO/70017/2006, POCI/CTM/59425/2004.por
dc.language.isoengen
dc.publisherIEEEen
dc.rightsrestrictedAccessen
dc.subjectLab-on-a-chipen
dc.subjectPVDFen
dc.subjectAcoustic microagitationen
dc.subjectSU-8en
dc.titleLab-on-a-chip with fluid acoustic microagitation : piezoelectric polymer β-PVDF used as ultrassonic transduceren
dc.typeconferencePaperen
dc.peerreviewedyesen
oaire.citationStartPage262por
oaire.citationEndPage+por
dc.subject.wosScience & Technologypor
sdum.bookTitleBIODEVICES 2008: PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, VOL 2por
Aparece nas coleções:DEI - Artigos em atas de congressos internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
BioDevices2008.pdf
Acesso restrito!
Documento principal1,37 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID