Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/17154

Registo completo
Campo DCValorIdioma
dc.contributor.authorGonzález-Pérez, Javier-
dc.contributor.authorGonzález-Méijome, José Manuel-
dc.contributor.authorRodríguez Ares, María T.-
dc.contributor.authorParafita, Manuel A.-
dc.date.accessioned2012-02-16T11:20:15Z-
dc.date.available2012-02-16T11:20:15Z-
dc.date.issued2011-
dc.identifier.issn1542-2321por
dc.identifier.issn1542-233Xpor
dc.identifier.urihttps://hdl.handle.net/1822/17154-
dc.description.abstractPurpose: To evaluate the effect of an acoustic factor (AF) on the comparison of central corneal thickness (CCT) and peripheral corneal thickness (PCT) measurements with Orbscan II and Pentacam. Methods: The CCT and PCT at 1, 2, and 3 radial distances from the corneal apex were measured using Orbscan II and Pentacam in 22 right eyes of 22 healthy adults (7 men, 15 women). Three measures were obtained from each 1 of the 25 points measured and then compared to gauge the agreement between both devices at the corneal center and anular areas located at 1-, 2-, and 3-mm distances from the central measurement. Orbscan II readings were considered with and without an AF correction. Results: Pentacam provides statistically significant higher values than Orbscan II does at all the 25 locations analyzed (P,0.001). With a few exceptions, the average difference was fairly constant between 20 and 40 mm for all the corneal locations. A high correlation existed between central readings (r2=0.927; P,0.001) and average thickness at each one of the annular areas being analyzed (r2=0.897 at 1 mm, r2=0.876 at 2 mm, and r2=0.870 at 3 mm); Pentacam minus Orbscan II value averaged for all the points changed from 228610 to 22269 mm after the removal of the AF in Orbscan II. Conclusions: Central and peripheral measurements of the corneal thickness obtained with Orbscan II and Pentacam are significantly different. The removal of the AF in Orbscan II renders lower mean differences but decreases the agreement between both systems and potentially induces an overestimation of CCT and PCT by Orbsan II compared with Pentacam.por
dc.description.sponsorshipSupported by national grant PI081380 from Instituto de Salud Carlos III, Spain granted to Ocular Surface and Contact Lens Research Group GI-1750.por
dc.language.isoengpor
dc.publisherLippincott, Williams & Wilkinspor
dc.rightsopenAccesspor
dc.subjectPachometrypor
dc.subjectPeripheral corneal thicknesspor
dc.subjectPentacampor
dc.subjectOrbscan IIpor
dc.subjectBlandpor
dc.subjectAltmanpor
dc.subjectBland-Altmanpor
dc.titleTopographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factorpor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttp://journals.lww.com/pages/default.aspxpor
sdum.publicationstatuspublishedpor
oaire.citationStartPage348por
oaire.citationEndPage353por
oaire.citationIssue6por
oaire.citationTitleEye & Contact Lenspor
oaire.citationVolume37por
dc.date.updated2012-01-04T14:15:15Z-
dc.identifier.doi10.1097/ICL.0b013e3182323dcfpor
dc.identifier.pmid21983548por
dc.subject.wosScience & Technologypor
sdum.journalEye & Contact Lens: Science and Clinical Practicepor
Aparece nas coleções:ICVS - Artigos em revistas internacionais / Papers in international journals
CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
5.5.65. GONZALEZ-PEREZ_11_ECL (PeripheralCTwithPentacam&rbscan).pdf401,51 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID