Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/22431

Registo completo
Campo DCValorIdioma
dc.contributor.authorSacht, Helenice Maria-
dc.contributor.authorBragança, L.-
dc.contributor.authorAlmeida, Manuela Guedes de-
dc.contributor.authorCaram, Rosana-
dc.date.accessioned2013-01-09T14:45:50Z-
dc.date.available2013-01-09T14:45:50Z-
dc.date.issued2012-06-28-
dc.identifier.urihttps://hdl.handle.net/1822/22431-
dc.description.abstractThe daylighting performance improvement is one better strategy to reduce the artificial lighting consumption in buildings and obviously requires solar radiation from the exterior. Daylighting comes not only from direct sunlight but also from illumination provided by the sky on overcast days. Particular attention must be given to daylighting while designing a building when the aim is to maximize visual comfort or to reduce energy consumption. Visual comfort of glazing façades is a fundamental characteristic to the global comfort. Additionally, this work reports a part of the results of an ongoing investigation about a new façade system concept: "Façade Modules for Eco-Efficient Refurbishment of Buildings", especially on the daylighting performance of double glazing modules. Ecotect 5.6 software was used to obtain the daylight factor and illuminance level for four Portugal cities and two double glazing façade modules, composed by green solar control glass and low-e glass; selfcleaning glass and float clear glass. A typical dwelling room (25m²) was simulated. Daylight factor and illuminance level were obtained by means of computational simulations. These results were compared to daylighting standards and recommendations. Results showed a better daylight performance for double self-cleaning glazing for all cities. A lower performance was observed when using green solar control glass and low-e glass.por
dc.description.sponsorshipErasmus Mundus - ISAC – Improving Skills Across Continentspor
dc.language.isoengpor
dc.publisherFundação de Desenvolvimento da UNICAMPpor
dc.rightsopenAccesspor
dc.subjectFaçadepor
dc.subjectGlazingpor
dc.subjectDaylighting performancepor
dc.subjectEcotectpor
dc.titleGlazing façade modules : daylighting performance simulation for Bragança, Coimbra, Évora and Faropor
dc.typeconferencePaper-
dc.peerreviewedyespor
sdum.publicationstatuspublishedpor
oaire.citationConferenceDate28 - 29 Jun. 2012por
sdum.event.typeconferencepor
oaire.citationStartPage533por
oaire.citationEndPage541por
oaire.citationConferencePlaceSão Paulo, Brasilpor
oaire.citationTitleSASBE2012 - 4th CIB International Conference on Smart and Sustainable Built Environmentspor
sdum.conferencePublicationSASBE2012 - 4th CIB International Conference on Smart and Sustainable Built Environmentspor
Aparece nas coleções:C-TAC - Comunicações a Conferências Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
sasbe2012_RS37803B.pdfDocumento Principal752,4 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID