dc.description.abstractNesta dissertação foi feita uma análise energética à área de distribuição e arrefecimento de águas, de uma fábrica de papel, com o objectivo de seguir as orientações propostas pelo SGCIE (Sistema de Gestão dos Consumos Intensivos de Energia). Este sistema de gestão é regulado segundo o decreto-lei 71/2008 de 15 de Abril e pressupõe um balanço energético da instalação, que neste caso trata-se de uma área sectorial que só representa cerca de 5 % do consumo total de energia da fábrica. Após o balanço é feita uma auditoria à instalação com o objectivo de propor alterações que aumentem a eficiência energética, reduzindo consumos e rácios de emissão de CO2 sem prejudicar o processo produtivo. Foram feitos estudos da rentabilidade da alteração de motores eléctricos por outros com maior rendimento, do aproveitamento térmico das águas de retorno da unidade fabril, das medidas para redução do consumo do ar comprimido e aumento da eficiência na sua produção e da aplicação prática de variadores de frequência em diversas bombas centrífugas para transporte de água. Em conclusão, o aproveitamento térmico das águas de retorno, mediante a aplicação de um permutador de calor e algumas alterações na distribuição da água, provou ser capaz de poupanças em energia térmica na ordem dos 14%, relativamente à área de distribuição e arrefecimento de águas. Concluiu-se também, que a aplicação de variadores de frequência em bombas centrífugas é igualmente bastante rentável, permitindo poupanças de energia eléctrica superiores a 7% da área total auditada.por
dc.description.abstractThe main objective of this thesis is the energy analysis of the distribution and water cooling system in a paper mill in order to comply with the guidelines proposed by SGCIE (Management System for Intensive Energy Consumers). This management system is regulated according to the Decree-Law 71/2008 of 15 April and requires an energy balance of the installation, which in this case, includes a sectorial area that only represents about 5% of the total energy consumption in all the plant. The energy balance was followed by a detailed audit of the installation with the aim to recommend changes that will increase energy efficiency, reducing fuel consumption and CO2 emissions, without negatively affecting the production process. Studies were made showing the relevance of changing electric motors by others with higher efficiency, of the thermal recovery of returned water, of the actions to reduce compressed air consumption and increase efficiency and the practical application of variable frequency motors to several centrifugal pumps. In conclusion, the thermal recovery of returned water, through the application of a heat exchanger and some modifications in the water distribution, proved to be able to reach savings of around 14% in thermal energy, relative to the area of the distribution and water cooling. It is also concluded, that the application of variable frequency drives on centrifugal pumps is also fairly cost effective, with electrical power savings of more than 7% of the analyzed installation.por
dc.language.isoporpor
dc.rightsopenAccesspor
dc.subjectEficiência energéticapor
dc.subjectEnergia eléctricapor
dc.subjectEnergia térmicapor
dc.subjectAuditoria energéticapor
dc.subjectSGCIEpor
dc.subjectVEVpor
dc.subjectCO2por
dc.subjectElectric efficiencypor
dc.subjectElectricitypor
dc.subjectThermal energypor
dc.subjectEnergy auditpor
dc.titleBalanço e poupança energética na distribuição de águas numa fábrica de papelpor
dc.typemasterThesis-
dc.subject.udc620.92-
dc.subject.udc676-
dc.identifier.tid201190109por
Aparece nas coleções:BUM - Dissertações de Mestrado
DEM - Dissertações de Mestrado / MSc Thesis

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Dissertacao_Nuno Saganha_2013.pdf3,48 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID