Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/37596

Registo completo
Campo DCValorIdioma
dc.contributor.authorAskari, Ehsanpor
dc.contributor.authorFlores, Paulopor
dc.contributor.authorDabirrahmani, Danépor
dc.contributor.authorAppleyard, Richardpor
dc.date.accessioned2015-10-09T10:56:02Z-
dc.date.available2015-10-09T10:56:02Z-
dc.date.issued2015-
dc.identifier.issn0924-090Xpor
dc.identifier.urihttps://hdl.handle.net/1822/37596-
dc.description.abstractWear plays a key role in primary failure of artificial hip articulations. Thus, the main goal of this work is to investigate the influence of friction-induced vibration on the predicted wear of hard hip arthroplasties. This desideratum is reached by developing a three-dimensional multibody dynamic model for a hip prosthesis taking the spatial nature of the physiological loading and motion of the human body into account. The calculation of the intra-joint contact forces developed is based on a continuous contact force approach that accounts for the geometrical and materials properties of the contacting surfaces. In addition, the friction effects due to the contact between hip components are also taken into account. The vibration of the femoral head inside the cup associated with stick-slip friction, negative-sloping friction and dynamic variation in intra-joint contact force has been also incorporated in the present hip articulation model. The friction-induced vibration increases the sliding distance of the contact point between the head and cup surfaces by altering its micro and macro trajectories, and consequently affects the wear. In the present work, the Archard’s wear law is considered and embedded in the dynamic hip multibody model, which allows for the prediction of the wear developed in the hip joint. With the purpose of having more realistic wear simulation conditions, the geometries of the acetabular cup and femoral head are updated throughout the dynamic analysis. The main results obtained from computational simulations for ceramic-on-ceramic and metal-on-metal hip prostheses are compared and validated with those available in the best-published literature. Finally, from the study performed in the present work, it can be concluded that that an important source of the high wear rates observed clinically may be due to friction-induced vibration.por
dc.description.sponsorshipThe first author gratefully acknowledges Macquarie University for his International Macquarie University Research Excellence Scholarship (iMQRES)-No. 2010017. The second author would like to thank the Portuguese Foundation for Science and Technology (FCT) through the project UID/EEA/04436/2013.por
dc.language.isoengpor
dc.publisherSpringer por
dc.relationFundação para a Ciência e a Tecnologia (FCT)por
dc.rightsopenAccesspor
dc.subjectWear simulationpor
dc.subjectArtificial hip articulationpor
dc.subjectFriction-induced vibrationpor
dc.subjectMultibody dynamicspor
dc.titleDynamic modeling and analysis of wear in spatial hard-on-hard couple hip replacements using multibody systems methodologiespor
dc.typearticlepor
dc.peerreviewedyespor
sdum.publicationstatuspublishedpor
oaire.citationStartPage1039por
oaire.citationEndPage1058por
oaire.citationIssue1-2por
oaire.citationTitleNonlinear Dynamicspor
oaire.citationVolume82por
dc.identifier.doi10.1007/s11071-015-2216-9por
dc.subject.fosEngenharia e Tecnologia::Engenharia Mecânicapor
dc.subject.wosScience & Technologypor
sdum.journalNonlinear Dynamicspor
Aparece nas coleções:DEM - Artigos em revistas de circulação internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
6.7.50 2015.pdfDocumento principal2 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID