Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/52929

TítuloQuasi-static and dynamic properties of the intervertebral disc: experimental study and model parameter determination for the porcine lumbar motion segment
Autor(es)Araújo, Ângelo Rafael Gomes
Peixinho, Nuno
Pinho, A. C. Marques
Claro, José Carlos Pimenta
Palavras-chaveIntervertebral disc
Dynamic response
Stiffness
Axial compression
Quasi-static response
Data2015
EditoraWroclaw University of Technology
RevistaActa of Bioengineering and Biomechanics
Resumo(s)Purpose: The study of axial loading is essential to determine the properties of intervertebral disc. The objectives of this work are (1) to quantify the mechanical properties of porcine lumbar intervertebral discs under static and cyclic compressive loading, and (2) to determine the parameters of a five-parameter rheological model for porcine and compare them with those obtained for human lumbar intervertebral discs. Methods: Thus, the porcine lumbar motion segments were subjected to quasi-static and dynamic compression tests. The quasi-static tests were used to obtain the static stiffness coefficient at different strain rates, while the data from the cyclic compressive tests were used to both determine the dynamic stiffness coefficient and to be fitted in a 5-parameter model, in order to simulate the creep response of the porcine intervertebral discs. Results: The results demonstrated that dynamic stiffness coefficient of porcine discs is between four and ten times higher than the static stiffness coefficient, depending on load applied. The parameters of the rheological model suggested a low permeability of nucleus and endplate during the fast response of porcine discs. In addition, the fast response in terms of displacement is four times higher than those documented for human discs. Conclusions: This study revealed that care must be taken on the comparison between porcine and human discs, since they present different behaviour under quasi-static and dynamic compressive loading.
TipoArtigo
URIhttps://hdl.handle.net/1822/52929
DOI10.5277/ABB-00153-2014-04
ISSN1509-409X
Arbitragem científicayes
AcessoAcesso restrito UMinho
Aparece nas coleções:CT2M - Artigos em revistas de circulação internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Quasi-static - A Bioengineering and Biomechanics.pdf
Acesso restrito!
490,83 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID