dc.description.abstractAdobe constructions account for a significant portion of the built heritage, associated with early building techniques, material accessibility and low-cost. Nonetheless, adobe buildings, due to their low mechanical properties and overturning resistance, are subject to early structural damage, such as cracking, separation of structural elements and, possibly, collapse in areas of high seismic hazard. The lack of maintenance and absence of adequate retrofitting techniques usually intensifies the loss of historic fabric. The current paper, aims at the structural assessment and seismic safety, in current conditions, of the Church of Kuno Tambo, a religious adobe structure of the 17th century, in Cusco region, in Peru. The inspection and diagnosis involved sonic testing and damage mapping, while ambient vibration tests revealed the modal response of the structure. The assessment of seismic vulnerability, together with the necessity of retrofitting measures were verified through nonlinear static and pushover parametric analyses, complemented with a macro-block limit analysis and a performance based assessment, under local seismic criteria. A more realistic response from dynamically induced ground motions was performed, by a nonlinear time history analysis, according to the Eurocode 8 framework. Through an integrated approach, in situ inspection, testing, numerical and analytical modelling are associated under the scope of reproducing the existing structural damage, the sequence of inelastic behavior and verification of the necessity of retrofitting measures.por
dc.description.sponsorshipThe current work is part of the Seismic Retrofitting Project, of the Getty Conservation Institute and was partly supported by FCT (Portuguese Foundation for Science and Technology), within the INFRARISK PhD program and ISISE, project UID/ECl/04029/2013.por
dc.language.isoengpor
dc.publisherElsevier Science Ltdpor
dc.relationinfo:eu-repo/grantAgreement/FCT/5876/147221/PTpor
dc.rightsopenAccesspor
dc.subjectAdobe historic constructionspor
dc.subjectSeismic vulnerabilitypor
dc.subjectStructural assessmentpor
dc.subjectNonlinear pushover analysispor
dc.subjectNonlinear dynamic analysispor
dc.subjectDamage surveypor
dc.subjectSonic testspor
dc.subjectDynamic identification testspor
dc.subjectLimit analysispor
dc.subjectHomogeneous modelling approachpor
dc.subjectDisplacement based approachpor
dc.titleStructural assessment and seismic vulnerability of earthen historic structures. Application of sophisticated numerical and simple analytical modelspor
dc.typearticle-
dc.peerreviewedyespor
oaire.citationStartPage488por
oaire.citationEndPage509por
oaire.citationVolume160por
dc.date.updated2019-01-14T20:09:44Z-
dc.identifier.doi10.1016/j.engstruct.2017.12.023por
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.subject.wosScience & Technology-
sdum.export.identifier5250-
sdum.journalEngineering Structurespor
Aparece nas coleções:ISISE - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Structuralassessmentandseismicvulnerabilityofearthenhistoricstructures.pdf2,66 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID