Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/58997

Registo completo
Campo DCValorIdioma
dc.contributor.authorCardoso, Vitor E. M.por
dc.contributor.authorRamos, N.por
dc.contributor.authorAlmeida, R.por
dc.contributor.authorPereira, Pedro F.por
dc.contributor.authorAlmeida, Manuela Guedes depor
dc.contributor.authorSousa, Ruipor
dc.date.accessioned2019-02-07T16:12:46Z-
dc.date.available2019-02-07T16:12:46Z-
dc.date.issued2018-09-
dc.identifier.citationCardoso V., Ramos N., Almeida R., Pereira P., Almeida Manuela G. In-situ and laboratory airtightness tests of structural insulated panels (SIPs) assemblies, 39th AIVC - 7th TightVent & 5th Venticool Conference - Smart ventilation for buildings, 2018por
dc.identifier.urihttps://hdl.handle.net/1822/58997-
dc.description.abstractOne of the main factors influencing building airtightness is the construction typology. As building environmental performance requirements raise so does the prevalence of less conventional envelope construction systems as modular structural insulated panels (SIPs) buildings. In this paper, the airtightness performance of a constructive solution based on SIPs was evaluated. Airtightness tests were performed on the laboratory according to the EN 12114-2000 methodology. One complete exterior wall assembly and another one with the inclusion of a window were tested to determine their performance as an effective air barrier. The impact of the window framing in the overall resistance to air leakage was also determined. Additionally, the airtightness of a dwelling using these SIPs was measured during the construction phase and after commissioning. The objective was not only the assessment of the ACH50 difference between the two stages, but also the comparison with  previously tested conventional envelopes on the same climate. Laboratory and field test data resulted in mismatching values. Workmanship and unforeseen leakage paths were found to be the main contributors to these findings. Moreover, the case study displayed a superior airtightness performance when compared to heavy type construction solutions, common amongst the Portuguese building stock. Additional work is needed to identify and quantify envelope airpaths in order to properly design lightweight buildings solutions. por
dc.description.sponsorshipFCT-Fundação para a Ciência e a Tecnologia, the funding of the Doctoral Grant PD/BD/135162/2017, through the Doctoral Programme EcoCoRe. This paper is a result of the project “H0ME ZERO”, with the reference POCI -01-0247-FEDER-017840, co-funded by the European Regional Development Fund (ERDF), through the Operational Programme for Competitiveness and Internationalization (COMPETE 2020), under the PORTUGAL 2020 Partnership Agreement HOME This work was financially supported by : Project POCI-01-0145-FEDER-007457 -CONSTRUCT -Institute of R&D In Structures and Construction funded by FEDER funds through COMPETE 2020 -Programa Operacional Competitividade e Internacionalização POCI – and by national funds through - Fundação para a Ciência e a Tecnologiapor
dc.language.isoengpor
dc.rightsopenAccesspor
dc.subjectAirtightnesspor
dc.subjectSIPspor
dc.titleIn-situ and laboratory airtightness tests of structural insulated panels (SIPs) assembliespor
dc.typeconferencePaperpor
dc.peerreviewedyespor
dc.relation.publisherversionhttp://aivc2018conference.org/por
dc.commentshttp://ctac.uminho.pt/node/2903por
oaire.citationConferenceDate18 Set. - 19 Set. 2018por
sdum.event.title39th AIVC - 7th TightVent & 5th Venticool Conference - Smart ventilation for buildingspor
sdum.event.typeconferencepor
oaire.citationConferencePlaceAntibes Juan-Les-Pins, Francepor
oaire.citationTitle39th AIVC - 7th TightVent & 5th Venticool Conference - Smart ventilation for buildings-
dc.date.updated2019-02-07T15:39:06Z-
dc.subject.fosEngenharia e Tecnologia::Engenharia Civilpor
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
Aparece nas coleções:C-TAC - Comunicações a Conferências Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2903-AIVC18_In-situ and laboratory airtightness tests of structural insulated panels (SIPs) assemblies.pdf714,51 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID