dc.identifier.citationZonno, G., Aguilar, R., Boroschek, R., & Lourenço, P. B. (2021). Environmental and ambient vibration monitoring of historical adobe buildings: applications in emblematic andean churches. International Journal of Architectural Heritage, 1-17por
dc.identifier.issn1558-3058por
dc.identifier.urihttps://hdl.handle.net/1822/67856-
dc.description.abstractThis paper presents the application of long-term environmental and structural remote monitoring in two emblematic 16th-century adobe churches located in southern Peru. The paper starts by presenting details of the planning and installation processes of the monitoring systems and continues with a detailed discussion of the results of almost two years of continuous monitoring. As expected, due to the large thermal inertia of the adobe systems and size of the buildings, the results of the environmental monitoring indicated a non-uniform distribution of temperature and relative humidity inside the buildings, and an important attenuation of the internal conditions in comparison with the external ones. On the other hand, the structural monitoring results evidenced an annual cyclical behavior of the natural frequencies with an apparent correspondence with the changes in environmental conditions due to seasonal influences. The correlation of ambient conditions and structural parameters confirmed the high affinity between relative humidity measurements and natural frequencies when hourly fluctuations were removed from the measurements. An important novelty is the affinity of structural dynamic properties and a single environmental variable, the absolute humidity, was also evidenced since high determination coefficients were obtained when it was compared with the identified natural frequencies.por
dc.description.sponsorship- This work was supported by the CONCYTEC [No 222-2015-FONDECYT]; Pontificia Universidad Catolica del Peru [DGI 349-2016]; ELARCH program [552129-EM-1-2014-1-IT-ERA MUNDUS-EMA21].por
dc.language.isoengpor
dc.publisherTaylor and Francispor
dc.rightsrestrictedAccesspor
dc.subjectAdobe buildingspor
dc.subjectAndean churchespor
dc.subjectCorrelation analysispor
dc.subjectEnvironmental monitoringpor
dc.subjectStructural monitoringpor
dc.titleEnvironmental and ambient vibration monitoring of historical adobe buildings: applications in emblematic Andean Churchespor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttps://www.tandfonline.com/doi/full/10.1080/15583058.2019.1653402por
oaire.citationStartPage1113por
oaire.citationEndPage1129por
oaire.citationIssue8por
oaire.citationVolume15por
dc.date.updated2020-10-29T09:52:44Z-
dc.identifier.doi10.1080/15583058.2019.1653402por
dc.date.embargo10000-01-01-
dc.subject.fosEngenharia e Tecnologia::Engenharia Civilpor
dc.subject.wosArts & Humanities-
dc.subject.wosScience & Technology-
sdum.export.identifier7428-
sdum.journalInternational Journal of Architectural Heritagepor
Aparece nas coleções:ISISE - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2019_EnvironmentalandAmbientVibrationMonitoringofHistoricalAdobeBuildingsApplicationsinEmblematicAndeanChurches.pdf
Acesso restrito!
8,78 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID