TítuloFinite element modeling and operational modal analysis of a historical masonry mosque
Autor(es)Aşıkoğlu, Abide
Avşar, Özgür
Lourenço, Paulo B.
Silva, Luís C.
Kaplan, Onur
Karanikoloudis, Georgios
Palavras-chaveEigenvalue Analysis
Finite Element Modeling
Historical Masonry Structure
Model Calibration
Operational Modal Analysis
Data2019
EditoraNational Technical University of Athens
RevistaCOMPDYN Proceedings
Resumo(s)Finite Element Modeling (FEM) and Operational Modal Analysis (OMA) is herein presented for the historical masonry Kütahya Kurşunlu Mosque within the framework of its seismic performance assessment. The historical structure is located in Turkey which has a high-level seismic activity. A FEM strategy was adopted to construct a numerical model of the structure considering a simplified three-dimensional geometry and a macro-modeling approach for the masonry. A representative numerical model of the existing structure was calibrated and improved according to the OMA results obtained from ambient vibration measurements, performed in-situ. The ambient vibration measurements were operated by using two triaxial accelerometers, that one of the accelerometers was regulated as a reference station whereas the other accelerometer was relocated to seven different points on the top of the walls. Identification of the experimental modal parameters was achieved by performing two different signal processing methodologies, namely the Enhanced Frequency Domain Decomposition (EFDD) and the Stochastic Subspace Identification - Unweighted Principal Components (SSI-UPC). Results obtained from both methods were compared in terms of the Modal Assurance Criterion (MAC) which considers the mode shapes derived in a specific range of frequency. The SSI-UPC method was employed in achieving the experimental modal response of the structure and the results were compared with the eigenvalue analysis results of the preliminary numerical model. A calibration process was carried out in terms of minimizing the difference between the experimental and numerical modal response by a trial and error approach and an average error of 4.9% was calculated for the modal frequencies of the first four global modes of vibration.
TipoArtigo em ata de conferência
URIhttps://hdl.handle.net/1822/68376
ISBN9786188284463
DOI10.7712/120119.7009.19300
ISSN2623-3347
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:ISISE - Comunicações a Conferências Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
19300.pdf1,56 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID