Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/85521

TítuloDevelopment of an open-source injection mold monitoring system
Autor(es)Gomes, Tiago E. P.
Cadete, Mylene S.
Ferreira, Jorge A. F.
Febra, Renato
Silva, João
Noversa, João Tiago Gomes
Pontes, A. J.
Neto, Victor
Palavras-chaveInjection molding tool monitoring
Information technology
Data acquisition
Graphical user interface
User-computer interface
Open source software
Low cost
Real time
Data29-Mar-2023
EditoraMultidisciplinary Digital Publishing Institute
RevistaSensors
CitaçãoGomes, T.E.P.; Cadete, M.S.; Ferreira, J.A.F.; Febra, R.; Silva, J.; Noversa, T.; Pontes, A.J.; Neto, V. Development of an Open-Source Injection Mold Monitoring System. Sensors 2023, 23, 3569. https://doi.org/10.3390/s23073569
Resumo(s)In the highly competitive injection molding industry, the ability to effectively collect information from various sensors installed in molds and machines is of the utmost relevance, enabling the development of data-based Industry 4.0 algorithms. In this work, an alternative to commercially available monitoring systems used in the industry was developed and tested in the scope of the TOOLING 4G project. The novelty of this system is its affordability, simplicity, real-time data acquisition and display in an intuitive Graphical User Interface (GUI), while being open-source firmware and software-based. These characteristics, and their combinations have been present in previous works, but, to the authors’ knowledge, not all of them simultaneously. The system used an Arduino microcontroller-based data acquisition module that can be connected to any computer via a USB port. Software was developed, including a GUI, prepared to receive data from both the Arduino module and a second module. In the current state of development, data corresponding to a maximum of six sensors can be visualized, at a rate of 10 Hz, and recorded for later usage. These capabilities were verified under real-world conditions for monitoring an injection mold with the objective of creating the basis of a platform to deploy predictive maintenance. Mold temperature, cavity pressure, 3-axis acceleration, and extraction force data showed the system can successfully monitor the mold and allowed the clear distinction between normal and abnormal operating patterns.
TipoArtigo
DescriçãoThe raw data collected during the case study can be found at: https://github.com/TEPGomes/OpenMMS-T4G/blob/cfa6e23c7fc02a645e31e06d299021cb0a3ce3e7/Real_World_Test/Case_Study_Raw_Data.csv (accessed on 23 March 2023).
URIhttps://hdl.handle.net/1822/85521
DOI10.3390/s23073569
ISSN1424-8220
e-ISSN1424-8220
Versão da editorahttps://www.mdpi.com/1424-8220/23/7/3569
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:BUM - MDPI

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
sensors-23-03569.pdf4,41 MBAdobe PDFVer/Abrir

Este trabalho está licenciado sob uma Licença Creative Commons Creative Commons

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID