TítuloRepeatability and agreement of swept-source optical coherence tomography and partial coherence interferometry biometers in myopes
Autor(es)Garcia Ardoy, Elisa
Mateos, Nuria
Roda, Laura
Torrado Sierra, Oscar
Baptista, António M. G.
Serra, Pedro M.
Palavras-chaveChild
Humans
Adolescent
Prospective Studies
Cross-Sectional Studies
Axial Length, Eye
Reproducibility of Results
Cornea
Biometry
Interferometry
Anterior Chamber
Tomography, Optical Coherence
Myopia
Agreement
axial length
repeatability
Data2023
EditoraTaylor & Francis
RevistaClinical and Experimental Optometry
CitaçãoElisa Garcia Ardoy, Nuria Mateos, Laura Roda, Oscar Torrado Sierra, António M Baptista & Pedro M Serra (2023) Repeatability and agreement of swept-source optical coherence tomography and partial coherence interferometry biometers in myopes, Clinical and Experimental Optometry, 106:7, 783-792, DOI: 10.1080/08164622.2022.2152312
Resumo(s)Background: The Myopia Master is a new biometer based on partial coherence interferometry especially dedicated to the follow-up of myopic patients. This study aims to assess the repeatability of the Myopia Master and evaluate its agreement with a swept-source optical coherence interferometry biometer (IOL Master 700).MethodsThis cross-sectional prospective study assessed the biometric parameters of two groups of myopes (age range: 8-16 years old), spectacle corrected (n = 60) and orthokeratology contact lens wearers (n = 60). One senior optometrist performed two consecutive measurements per instrument, which included axial length, mean keratometry and horizontal visible iris diameter (HVID). The repeatability of each device and the agreement between devices were assessed by the dispersion of the measurement differences, for AL, mean keratometry, corneal astigmatism and HVID.ResultsThe two biometers measured approximately the same value in both measurements. Test-retest repeatability tended to be lower than clinical significant thresholds, in particular, for AL and mean keratometry. Corneal-related parameters tended to have lower repeatability in the orthokeratology group, especially mean keratometry. The agreement between instruments revealed statistically significant differences between devices with the SS-OCT measuring longer eyes, steeper corneas and larger HVID.ConclusionsIn a paediatric population, the Myopia Master showed clinically acceptable repeatability levels, but the IOL Master 700 demonstrated superior repeatability. Eyes treated with orthokeratology may compromise the repeatability of the corneal-related parameters. The Myopia Master and the IOL Master 700 are repeatable devices appropriate for monitoring myopia progression, but the differences observed do not allow their use interchangeably.
TipoArtigo
DescriçãoPublished online: 12 Dec 2022
URIhttps://hdl.handle.net/1822/87043
DOI10.1080/08164622.2022.2152312
ISSN0816-4622
e-ISSN1444-0938
Versão da editorahttps://www.tandfonline.com/doi/abs/10.1080/08164622.2022.2152312
Arbitragem científicayes
AcessoAcesso restrito UMinho
Aparece nas coleções:CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Repeatability and agreement of swept-source optical coherence tomography and partial coherence interferometry biometers in myopes.pdf
Acesso restrito!
2,74 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID