Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/89974

Registo completo
Campo DCValorIdioma
dc.contributor.authorGonçalves, Sandra Beatriz Tomépor
dc.contributor.authorPeixoto, Alexandre Coumiotis Moreirapor
dc.contributor.authorFerreira da Silva, Alexandrepor
dc.contributor.authorCorreia, J. H.por
dc.date.accessioned2024-03-25T14:51:42Z-
dc.date.issued2015-05-01-
dc.identifier.issn0960-1317por
dc.identifier.urihttps://hdl.handle.net/1822/89974-
dc.description.abstractThis paper presents a detailed description of the design, fabrication and mechanical characterization of 3D microelectrode arrays (MEA) that comprise high aspect-ratio shafts and different penetrating lengths of electrodes (from 3 mm to 4 mm). The array's design relies only on a bulk silicon substrate dicing saw technology. The encapsulation process is accomplished by a medical epoxy resin and platinum is used as the transduction layer between the probe and neural tissue. The probe's mechanical behaviour can significantly affect the neural tissue during implantation time. Thus, we measured the MEA maximum insertion force in an agar gel phantom and a porcine cadaver brain. Successful 3D MEA were produced with shafts of 3 mm, 3.5 mm and 4 mm in length. At a speed of 180 mm min(-1), the MEA show maximum penetrating forces per electrode of 2.65 mN and 12.5 mN for agar and brain tissue, respectively. A simple and reproducible fabrication method was demonstrated, capable of producing longer penetrating shafts than previously reported arrays using the same fabrication technology. Furthermore, shafts with sharp tips were achieved in the fabrication process simply by using a V-shaped blade.por
dc.description.sponsorshipACP is supported by the Portuguese Foundation for Science and Technology (SFRH/BD/89509/2012). This work was also supported by FCT with the project reference FCOMP-01-0124-FEDER-010909 (FCT/PTDC/SAU-BEB/100392/2008).por
dc.language.isoengpor
dc.publisherIOP Publishing Ltdpor
dc.relationinfo:eu-repo/grantAgreement/FCT/FARH/SFRH%2FBD%2F89509%2F2012/PTpor
dc.relationFCOMP-01-0124- FEDER-010909(FCT/PTDC/SAU-BEB/100392/2008)por
dc.rightsclosedAccesspor
dc.subjectNeural electrodespor
dc.subjectDicing technologypor
dc.subjectMechanical characterizationpor
dc.titleFabrication and mechanical characterization of long and different penetrating length neural microelectrode arrayspor
dc.typearticle-
dc.peerreviewedyespor
oaire.citationIssue5por
oaire.citationVolume25por
dc.date.updated2024-03-14T12:23:11Z-
dc.identifier.doi10.1088/0960-1317/25/5/055014por
dc.date.embargo10000-01-01-
dc.subject.wosScience & Technology-
sdum.export.identifier13474-
sdum.journalJournal of Micromechanics and Microengineeringpor
Aparece nas coleções:DEI - Artigos em revistas internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Goncalves_2015_J._Micromech._Microeng._25_055014.pdf
Acesso restrito!
1,94 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID