Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/89978

Registo completo
Campo DCValorIdioma
dc.contributor.authorPinto-Borges, Henriquepor
dc.contributor.authorPinto, Joãopor
dc.contributor.authorCarvalho, Óscar Samuel Novaispor
dc.contributor.authorHenriques, Brunopor
dc.contributor.authorSilva, Filipe Samuelpor
dc.contributor.authorGomes, Josépor
dc.contributor.authorRamos, Antoniopor
dc.contributor.authorSouza, Júlio C.M.por
dc.date.accessioned2024-03-25T15:03:58Z-
dc.date.issued2023-
dc.identifier.citationHenrique Pinto-Borges, João Pinto, Oscar Carvalho, Bruno Henriques, Filipe Silva, José Gomes, Antonio Ramos, Júlio C.M. Souza, Stresses, friction, and wear on different materials and design for temporomandibular joint total joint replacement (TMJ TJR), Tribology International, Volume 178, Part A, 2023, 108051, ISSN 0301-679X, https://doi.org/10.1016/j.triboint.2022.108051.por
dc.identifier.issn0301-679X-
dc.identifier.urihttps://hdl.handle.net/1822/89978-
dc.descriptionAvailable online 10 November 2022por
dc.description.abstractThe purpose of the present study was to evaluate the coefficient of friction, wear volume, surface damage, and contacting stresses regarding different materials and condyle design for alloplastic temporomandibular joint total joint replacement (TMJ TJR). Spherical-and anatomical-shape condyle specimens were prepared from CoCrMo or Ti6Al4V alloys which were assessed against ultra-highly molecular weight polyethylene (UHMWPE) square specimens. On the wear assessment, reciprocating sliding pin-on-plate wear tests were performed considering usual TMJ TJR motion on 30 N normal loading, 1 Hz sliding frequency, and 4-mm linear stroke length for 60 min. Wear tests were performed in Ringer's solution at 37o C to mimic the surrounding environment. The co-efficient of friction and wear volume were recorded for the two condyle design and materials' pairs. The von Mises stresses and displacement were calculated using a 3D finite element model (FEM) simulation built on tetrahedral linear elements, performed relatively to the condyle-to-UHMWPE central axis. On anatomical TMJ TJR condyle, von Mises stresses were lower when compared to standard TMJ TJR condyle. Wear tests showed a low wear volume of UHMWPE against Ti6Al4V although the volume loss recorded for UHMWPE was lower on the anatomical-shape condyle than that for the spherical design. Scanning electron microscopy revealed plastic deformation on the UHMWPE resulting in ploughing and materials' degradation after wear testing. Thus, an anatomical TMJ TJR condyle design revealed lower stress distribution and wear volume when compared to a standard TMJ TJR condyle that could improve the long-term mechanical integrity of TMJ TJR over cyclic loading.por
dc.description.sponsorshipThe authors acknowledge the financial support provided by the Portuguese Foundation for Science and Technology (FCT), Portugal, namely UID/EEA/04436/2013, SFRH/BPD/123769/2016, and Project Laser MULTICER (POCI-01-0145-FEDER-031035).por
dc.language.isoengpor
dc.publisherElsevier 1por
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UID%2FEEA%2F04436%2F2013/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/POR_NORTE/SFRH%2FBPD%2F123769%2F2016/PTpor
dc.rightsrestrictedAccesspor
dc.subjectTemporomandibular jointpor
dc.subjectTMJ TJRpor
dc.subjectFrictionpor
dc.subjectWearpor
dc.subjectBiotribologypor
dc.titleStresses, friction, and wear on different materials and design for temporomandibular joint total joint replacement (TMJ TJR)por
dc.typearticlepor
dc.peerreviewedyespor
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S0301679X22006223por
oaire.citationStartPage1por
oaire.citationEndPage13por
oaire.citationVolume178por
dc.date.updated2024-03-20T23:43:28Z-
dc.identifier.eissn1879-2464-
dc.identifier.doi10.1016/j.triboint.2022.108051por
dc.date.embargo10000-01-01-
dc.subject.wosScience & Technology-
sdum.export.identifier13618-
sdum.journalTribology Internationalpor
dc.identifier.articlenumber108051por
Aparece nas coleções:CMEMS - Artigos em revistas internacionais/Papers in international journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Stresses, friction, and wear on different materials and design for temporomandibular joint total joint replacement (TMJ TJR).pdf
Acesso restrito!
7,13 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID