Utilize este identificador para referenciar este registo:
https://hdl.handle.net/1822/35033
Título: | Performance of three multipurpose disinfecting solutions with a silicone hydrogel contact lens |
Autor(es): | García-Porta, Nery Rico-del-Viejo, L. Neves, Helena Matos, Sofia Cláudia Peixoto de Queirós, A. González-Méijome, José Manuel |
Data: | 2015 |
Editora: | Hindawi Publishing Corporation |
Revista: | BioMed research international |
Citação: | García-Porta, Nery; Rico-del-Viejo, Laura; Neves, Helena; Peixoto-de-Matos, Sofia Claudia; Queirós, António; González-Méijome JM. Performance of Three Multipurpose Disinfecting Solutions with a Silicone Hydrogel Contact Lens, BioMed Research International , 216932, 1, 1-13, 2015. |
Resumo(s): | To evaluate the clinical performance of a silicone hydrogel (Si-Hy) soft contact lens (CL) in combination with three differentmultipurpose disinfecting solutions (MPDSs).Methods.Thiswas a prospective, randomized, single-masked, crossover, and comparative study in which 31 habitual soft CL wearers were randomly assigned to one of the three MPDSs (Synergi, COMPLETE RevitaLens, and OPTI-FREE PureMoist) for 1 month with a 1-week wash-out period between each exposure. All subjects were successfully refitted with a Si-Hy CL (Biofinity). Subjects were then scheduled for follow-up visits after 1 month of lens wear, being evaluated at 2 and 8 hours after lens insertion. Visual Analogue Scales (VAS) were used to gauge comfort rating. Results. The tarsal conjunctiva showed a significantly different degree of lid redness between the MPDSs at the 2-hour visit (P < 0.05, Kruskal- Wallis test), being lower for COMPLETE RevitaLens compared to the other two MPDSs (Mann-Whitney U test). Furthermore, a significantly different degree of lid roughness at the 8-hour visit was seen (P < 0.05, Kruskal-Wallis test), being higher for Synergi (Mann-Whitney U test).Thesubjective comfort was similar with the threeMPDSs. Conclusion. Tarsal conjunctival response should be also considered in the context of the clinical performance of MPDs at the ocular surface. |
Tipo: | Artigo |
Descrição: | "Article ID 216932" |
URI: | https://hdl.handle.net/1822/35033 |
DOI: | 10.1155/2015/216932 |
ISSN: | 2314-6133 2314-6141 |
Versão da editora: | http://dx.doi.org/10.1155/2015/216932 |
Arbitragem científica: | yes |
Acesso: | Acesso aberto |
Aparece nas coleções: | CDF - OCV - Artigos/Papers (with refereeing) |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
GARCIA-PORTA_2105 (Performance of Three Multipurpose Disinfecting Solutions with a Silicone Hydrogel CL).pdf | 2,11 MB | Adobe PDF | Ver/Abrir |