TítuloShaking table testing for masonry infill walls: unreinforced versus reinforced solutions
Autor(es)Lourenço, Paulo B.
Leite, João M.
Paulo-Pereira, Manuel F.
Campos-Costa, A.
Candeias, P. X.
Mendes, N.
Palavras-chaveMasonry infills
Reinforced concrete frame
Bed joint reinforcement
Reinforced plaster
Shaking table tests
Earthquake engineering.
Data2016
EditoraWiley
RevistaEarthquake Engineering & Structural Dynamics
CitaçãoLourenço, P. B., Leite, J. M., Paulo-Pereira, M. F., Campos-Costa, A., Candeias, P. X., & Mendes, N. (2016). Shaking table testing for masonry infill walls: unreinforced versus reinforced solutions. Earthquake Engineering and Structural Dynamics, 45(14), 2241-2260. doi: 10.1002/eqe.2756
Resumo(s)Several factors influence the behaviour of infilled frames, which have been a subject of research in the past with moderate success. The new generation of European design standards imposes the need to prevent brittle collapse of the infills and makes the structural engineer accountable for this requirement, yet it fails to provide sufficient information for masonry infills design. Therefore, the present work aims at understanding the seismic behaviour of masonry infill walls within reinforced concrete frames, using both unreinforced and reinforced solutions (bed joint reinforcement and reinforced plaster). For this purpose, three reinforced concrete buildings with different infill solutions were constructed at a scale of 1:1.5, all with the same geometry, and were tested on the shaking table of the National Laboratory for Civil Engineering, Portugal. All solutions performed adequately for the design earthquake, with no visible damage. Still, the experimental tests show that the double-leaf-unreinforced infill walls underperformed during a large earthquake, collapsing out of plane by rotating as rigid bodies with multiple configurations. Also the reinforced concrete buildings collapsed, because of the adverse interaction with the infill walls. The infill walls with bed joint reinforcement and reinforced plaster did not collapse out of plane, because of their connection to the concrete frame, which is an essential requirement.
TipoArtigo
URIhttps://hdl.handle.net/1822/44917
DOI10.1002/eqe.2756
ISSN0098-8847
e-ISSN1096-9845
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:ISISE - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Earth Eng and Stru Design_RG.pdf3,14 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID