Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/63248

Registo completo
Campo DCValorIdioma
dc.contributor.authorRezende, M. L. Souzapor
dc.contributor.authorCamões, Airespor
dc.contributor.authorEires, R.por
dc.contributor.authorJesus, Carlos Manuel Gonçalvespor
dc.contributor.authorSoares, E.por
dc.date.accessioned2020-01-16T17:23:50Z-
dc.date.available2020-01-16T17:23:50Z-
dc.date.issued2019-02-
dc.identifier.citationRezende M. L., Camões A., Eires R., Jesus C. M. G., Soares E. Proposta de Ensaio Acelerado de Exposição a Chuvas Dirigidas, TEST&E 2019, 2º Congresso de Ensaios e Experimentação em Engenharia Civil, 2019por
dc.identifier.isbn978-972-8574-49-9por
dc.identifier.urihttps://hdl.handle.net/1822/63248-
dc.description.abstractO efeito erosivo da chuva dirigida (chuva carregada pelo vento), é considerado um dos principais agentes de degradação nas fachadas de edificações, causando desde problemas estéticos a decomposição dos elementos que as compõem. Devido a atual tendência de uso de materiais de construção não convencionais, torna-se necessária a avaliação do desempenho destes quando em uso e, no caso de componentes para alvenarias externas, a resistência dos mesmos à ação de chuvas dirigidas. Os testes prescritos em normas internacionais são específicos para as condições climáticas do país ou região em que são adotados, havendo a necessidade de adaptações utilizando-se parâmetros coerentes com os dados meteorológicos da região para a qual o material se destina. Neste trabalho é apresentada uma proposta de equipamento de ensaio e descrita a metodologia para levantamento de dados e validação do teste por meio da correlação dos parâmetros adotados com os dados de caracterização de chuvas em Portugal. Foram avaliados diversos fatores, entre os quais o diâmetro da gota, velocidade, distância de aplicação e tempo de exposição. Tendo em vista que o potencial erosivo da chuva natural é medido em função da energia cinética, o teste e a metodologia proposta mostraram- se eficientes em simular a incidência de chuvas em vedações verticais externas, sendo possível, em duas horas de teste, acelerar o desgaste equivalente a 50 anos de exposição na região de maior índice pluviométrico de Portugal.por
dc.description.abstractThe erosive effect of directed rain (rain that is carried by the wind) is considered one of the main agents of degradation in buildingsfaçades, causing ranging fromaesthetic problems to the decomposition of the elements that compose them. Due to the current trend of using non-conventional building materials, it is necessary to evaluate the performance of these materials when in use and, in the case of external masonry components, its resistance to driving rain. The tests prescribed in international standards are specific to the climatic conditions of the country or region in which they are assumed,with the necessity of adaptations using parameters consistent with the meteorological data of the region for which the material is intended. This paper presents a proposal for test equipment and described the methodology for data collection and validation of the testthrough the correlation between the adopted parameters with data of characterization of precipitation in Portugal.Several factors were evaluated, including drop diameter, velocity, application distance and time of exposure. Considering that the erosive potential of natural rainfall is measured as a function of kinetic energy, the test and the proposed methodology were efficient in simulating the incidence of rainfall in external vertical masonry, being possible, intwo hours of test, accelerate wear equivalent to 50 years of exposure in the region with the highest rainfall in Portugalpor
dc.language.isoporpor
dc.publisherRelacrepor
dc.rightsopenAccesspor
dc.subjectChuva dirigidapor
dc.subjectErosãopor
dc.titleProposta de ensaio acelerado de exposição a chuvas dirigidaspor
dc.title.alternativeProposal of accelerated test exposure to driving rainpor
dc.typeconferencePaperpor
dc.peerreviewedyespor
dc.relation.publisherversionhttps://www2.isep.ipp.pt/teste2019/index.php?page=livro-de-ataspor
dc.commentshttp://ctac.uminho.pt/node/3086por
oaire.citationConferenceDate19 Fev. - 21 Fev. 2019por
sdum.event.titleTEST&E 2019 - 2º Congresso de Ensaios e Experimentação em Engenharia Civilpor
sdum.event.typecongresspor
oaire.citationStartPage625por
oaire.citationEndPage633por
oaire.citationConferencePlacePorto, Portugalpor
dc.date.updated2020-01-16T12:13:17Z-
dc.subject.fosEngenharia e Tecnologia::Engenharia Civilpor
sdum.conferencePublicationAtas do 2º Congresso de Ensaios e Experimentação em Engenharia Civilpor
Aparece nas coleções:C-TAC - Comunicações a Conferências Nacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
3086-Rezende et al.pdf1,32 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID