Comparison of current-source and voltage-source shunt active power filters for harmonic compensation and reactive power control
| dc.contributor.author | Pinto, J. G. | |
| dc.contributor.author | Exposto, Bruno Fernandes | |
| dc.contributor.author | Monteiro, Vítor Duarte Fernandes | |
| dc.contributor.author | Monteiro, Luís F. C. | |
| dc.contributor.author | Couto, Carlos | |
| dc.contributor.author | Afonso, João L. | |
| dc.date.accessioned | 2012-11-29T17:21:46Z | |
| dc.date.available | 2012-11-29T17:21:46Z | |
| dc.date.issued | 2012-10 | |
| dc.description.abstract | This paper presents the comparison between two three-phase Shunt Active Power Filters (SAPFs), one with Current-Source Inverter (CSI) and the other with Voltage-Source Inverter (VSI), which are used to compensate current harmonics and to control reactive power. The control algorithm of both SAPFs is based on the Instantaneous Reactive Power Theory (p-q Theory). The comparison here presented focuses on the Total Harmonic Distortion (THD) and RMS values of the compensated currents, and in the Total Power Factor (TPF) of the installation. | por |
| dc.description.sponsorship | Fundação para a Ciência e a Tecnologia (FCT) | por |
| dc.distribution | international | por |
| dc.identifier.doi | 10.1109/IECON.2012.6389552 | por |
| dc.identifier.isbn | 978-1-4673-2420-5 | |
| dc.identifier.issn | 1553-572X | por |
| dc.identifier.uri | https://hdl.handle.net/1822/21078 | |
| dc.language.iso | eng | por |
| dc.peerreviewed | yes | por |
| dc.publisher | IEEE | por |
| dc.relation | info:eu-repo/grantAgreement/FCT/5876-PPCDTI/104569/PT | |
| dc.rights | openAccess | por |
| dc.subject | Power quality | por |
| dc.subject | Harmonics | por |
| dc.subject | Reactive power | por |
| dc.subject | Shunt active power filter | por |
| dc.subject | Phase-locked loop | por |
| dc.subject | Digital control | por |
| dc.subject | Voltage-source inverter (VSI) | por |
| dc.subject | Current-source inverter (CSI) | por |
| dc.subject.wos | Science & Technology | por |
| dc.title | Comparison of current-source and voltage-source shunt active power filters for harmonic compensation and reactive power control | por |
| dc.type | conferencePaper | por |
| dspace.entity.type | Publication | en |
| oaire.citationConferencePlace | Montreal, Canada | por |
| oaire.citationEndPage | 5148 | por |
| oaire.citationStartPage | 5143 | por |
| oaire.citationTitle | 38th Annual Conference of the IEEE Industrial Electronics Society – IECON2012 | por |
| sdum.conferencePublication | 38th Annual Conference of the IEEE Industrial Electronics Society – IECON2012 | por |
| sdum.journal | IEEE Open Journal of the Industrial Electronics Society | por |
| sdum.publicationstatus | published | por |
Ficheiros
Pacote original
1 - 1 de 1
A carregar...
- Nome:
- IECON_2012_C_CSI_VSI_SAPF.pdf
- Tamanho:
- 944 KB
- Formato: