Development of a perioperative thermal insulation system: Testing comfort properties for different textile sets

dc.contributor.authorCarvalho, Isaurapor
dc.contributor.authorCarvalho, Miguelpor
dc.contributor.authorFontes, Liliana Magalhães Campospor
dc.contributor.authorMartins, Teresapor
dc.contributor.authorAbelha, Fernandopor
dc.date.accessioned2024-04-02T21:36:51Z
dc.date.available2024-04-02T21:36:51Z
dc.date.issued2023
dc.date.updated2024-04-02T16:30:01Z
dc.descriptionData Availability: All relevant data are within the manuscript. Supplementary data files are available: https://doi.org/10.5061/dryad.np5hqbzx7.por
dc.description.abstractThe poorly physical and psychological conditions of the patients make the body thermal protection crucial in the perioperative context, due to the risk of hypothermia. The lack of evidence regarding the effectiveness of textile coverings in protecting patients in the operating room, underscores the recommendation of the forced warming system using non-woven fabric for ensuring the best thermal protection in the perioperative context. This study is part of a development process of a three-layered thermal insulation system, a blanket for use in the perioperative context. After previous selection of two fabrics for the mid and outer layers, in this study three fabric samples for the inner layer with same soft tactile sensation and different textile compositions were tested to find its effect on increasing the thermal insulation of the whole set, using a thermal manikin. The serial method was used to calculate the thermal insulation properties of the sets. The best thermal insulation and thermal comfort performance was obtained by the set using an inner layer composed of polypropylene, polyamide, and elastane whose results were the highest thermal conductivity and thickness and the lowest maximum stationary heat flow density. The results indicated that this fabric influenced positively the values of the whole set once increased its thermal protection effectiveness when compared to the other tested sets. This set is more suitable for future testing in patients during their stay in the perioperative setting.por
dc.description.sponsorshipThis work is financed by national funds through FCT - Portuguese Foundation for Science and Technology under the project UIDB/4255/2020 and reference UIDP/4255/2020. The funders had no role in study design, data collection, and analysis, decision to publish, or preparation of the manuscript.por
dc.distributioninternationalpor
dc.identifier.citationCarvalho I, Carvalho M, Fontes L, Martins T, Abelha F (2023) Development of a perioperative thermal insulation system: Testing comfort properties for different textile sets. PLoS ONE 18(9): e0291424. https://doi.org/10.1371/journal.pone.0291424por
dc.identifier.doi10.1371/journal.pone.0291424por
dc.identifier.eissn1932-6203por
dc.identifier.pmc37699056
dc.identifier.pmid37699056por
dc.identifier.urihttps://hdl.handle.net/1822/90441
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherPLOSpor
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F04255%2F2020/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDP%2F04255%2F2020/PTpor
dc.relation.publisherversionhttps://journals.plos.org/plosone/article?id=10.1371/journal.pone.0291424por
dc.rightsopenAccesspor
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/por
dc.subject.fosEngenharia e Tecnologia::Engenharia dos Materiaispor
dc.titleDevelopment of a perioperative thermal insulation system: Testing comfort properties for different textile setspor
dc.typearticle
dspace.entity.typePublicationen
oaire.citationIssue9 Septemberpor
oaire.citationVolume18por
sdum.export.identifier14967
sdum.journalPLoS ONEpor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
Development of a perioperative thermal insulation system Testing comfort properties for different textile sets Enhanced Reader.pdf
Tamanho:
7.63 MB
Formato:
Adobe Portable Document Format