Feasibility and accuracy of automated three-dimensional echocardiographic analysis of left atrial appendage for transcatheter closure

dc.contributor.authorMorais, Pedropor
dc.contributor.authorFan, Yitingpor
dc.contributor.authorQueirós, Sandro Filipe Monteiropor
dc.contributor.authorD'hooge, Janpor
dc.contributor.authorLee, Alex Pui-Waipor
dc.contributor.authorVilaça, João Lpor
dc.date.accessioned2022-03-22T13:38:36Z
dc.date.available2023-02-01T07:00:31Z
dc.date.issued2022-01
dc.description.abstractProcedural success of transcatheter left atrial appendage closure (LAAC) is dependent on correct device selection. Three-dimensional (3D) transesophageal echocardiography (TEE) is more accurate than the two-dimensional modality for evaluation of the complex anatomy of the left atrial appendage (LAA). However, 3D transesophageal echocardiographic analysis of the LAA is challenging and highly expertise dependent. The aim of this study was to evaluate the feasibility and accuracy of a novel software tool for automated 3D analysis of the LAA using 3D transesophageal echocardiographic data.por
dc.description.sponsorshipThis work was funded by the projects “NORTE-01-0145-FEDER-000045” and “NORTE-01-0145-FEDER-000059”, supported by Northern Portugal Regional Operational Programme (Norte2020), under the Portugal 2020 Partnership Agreement, through the European Regional Development Fund (FEDER). It was also funded by national funds, through the FCT – Fundação para a Ciência e Tecnologia and FCT/MCTES in the scope of the project UIDB/05549/2020 and UIDP/05549/2020 and the grant CEECIND/03064/2018. This work was also funded by the Hong Kong Special Administrative Region Government Health and Medical Research Fund (05160976).por
dc.distributioninternationalpor
dc.identifier.doi10.1016/j.echo.2021.08.023por
dc.identifier.issn0894-7317por
dc.identifier.pmid34508840por
dc.identifier.urihttps://hdl.handle.net/1822/76616
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.relationinfo:eu-repo/grantAgreement/FCT/CEEC IND 2018/CEECIND%2F03064%2F2018%2FCP1581%2FCT0017/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F05549%2F2020/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDP%2F05549%2F2020/PTpor
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S0894731721007021por
dc.rightsopenAccesspor
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/por
dc.subjectEchocardiography, Transesophagealpor
dc.subjectAtrial Appendagepor
dc.subjectEchocardiography, Three-Dimensionalpor
dc.subjectLeft atrial appendage closurepor
dc.subjectLAA device sizingpor
dc.subjectAutomated software analysispor
dc.subjectInteractive analysispor
dc.subject3D transesophageal echocardiographypor
dc.subject.wosScience & Technologypor
dc.titleFeasibility and accuracy of automated three-dimensional echocardiographic analysis of left atrial appendage for transcatheter closurepor
dc.typearticleeng
dspace.entity.typePublicationen
oaire.citationEndPage133por
oaire.citationIssue1por
oaire.citationStartPage124por
oaire.citationVolume35por
oaire.versionAMpor
sdum.journalJournal of the American Society of Echocardiographypor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
PMorais_JASE_2022_accepted.pdf
Tamanho:
780.29 KB
Formato:
Adobe Portable Document Format
Descrição: