Accuracy of Invisalign® on upper incisors: a systematic review

dc.contributor.authorGonçalves, Alinepor
dc.contributor.authorCollard, Athénaïspor
dc.contributor.authorMonteiro, Francisca Machadopor
dc.contributor.authorMatos, Davidpor
dc.contributor.authorCarvalho, Óscar Samuel Novaispor
dc.contributor.authorAzevedo, Ruipor
dc.contributor.authorSilva, Filipe Samuelpor
dc.contributor.authorPinho, Teresapor
dc.date.accessioned2024-03-25T11:45:16Z
dc.date.embargo10000-01-01
dc.date.issued2023
dc.date.updated2024-03-20T23:13:03Z
dc.description.abstractThe current systematic review appraises the effectiveness of the types of tooth movements performed with Invisalign® clear aligner on the maxillary incisors. An electronic literature search of published trials was performed through PubMed, LILACS, Scopus, Cochrane Library, and Web of Science databases, and selected journals, from 2009 to 2020. Out of 291 references, five relevant publications were identified for analysis: four studies were performed retrospectively and one prospectively, all non-randomized. Despite the limited set of selected articles, the sample size is significant, with 148 subjects included in the reviewed studies involving the orthodontic treatment of upper incisors. We concluded that movements with the Invisalign® clear aligner on the upper incisors present distinct accuracy, possibly related with movement complexity; intrusion of the incisors has low accuracy (in some cases, 0% of accuracy was reported when the tooth extruded), while incisor extrusion exhibit some of the highest accuracy values reported in the included studies (45%-142%, when the achieved movement was greater than the predicted). Besides, axial (i.e., torque and tip) and horizontal (i.e., translation and rotation) movements are usually effective, with accuracy values between 39%-156% and 42%-79%, respectively. Overall, we determined that the efficiency of aligner to reach the desired movements in the upper incisors was low, as often refinements were required in the included studies. The use of aligner features must be more often considered to improve movement accuracy.por
dc.description.sponsorshipThis systematic review was supported by UNIPRO - Oral Pathology and Rehabilitation Research Unit in the scope of AlignAgen-GI2-CESPU-2022 and by FCT (Fundação para a Ciência e Tecnologia) through the grant 2020.09375.BD and in the scope of the project UIDB/04436/2020 and UIDP/04436/2020.por
dc.distributioninternationalpor
dc.identifier.citationGonçalves A, Collard A, Monteiro F, Matos D, Carvalho Ó, Azevedo R, Silva FS, Pinho T. Accuracy of Invisalign® on Upper Incisors: A Systematic Review. Turk J Orthod. 2023; 36(2): 126-133por
dc.identifier.doi10.4274/TurkJOrthod.2022.2021.0254por
dc.identifier.eissn2148-9505
dc.identifier.issn2528-9659
dc.identifier.urihttps://hdl.handle.net/1822/89946
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherTurkish Orthodontic Societypor
dc.relationAlignAgen-GI2-CESPU-2022por
dc.relationinfo:eu-repo/grantAgreement/FCT/POR_NORTE/2020.09375.BD/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F04436%2F2020/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDP%2F04436%2F2020/PTpor
dc.relation.publisherversionhttps://www.turkjorthod.org/archives/archive-detail/article-preview/accuracy-of-nvisalignsup-sup-on-upper-ncisors-a-sy/58630por
dc.rightsclosedAccesspor
dc.subjectAccuracypor
dc.subjectEfficiencypor
dc.subjectIncisorpor
dc.subjectInvisalign®por
dc.subjectTooth movementpor
dc.titleAccuracy of Invisalign® on upper incisors: a systematic reviewpor
dc.typearticlepor
dspace.entity.typePublicationen
oaire.citationEndPage133por
oaire.citationIssue2por
oaire.citationStartPage126por
oaire.citationVolume36por
sdum.export.identifier13604
sdum.journalTurkish Journal of Orthodonticspor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
Accuracy of Invisalign® on Upper Incisors-A Systematic Review.pdf
Tamanho:
635.96 KB
Formato:
Adobe Portable Document Format