Comparative analysis of visual and cognitive performance in esports athletes and soccer players

dc.contributor.authorJorge, Jorge
dc.contributor.authorCymbron, Filipe
dc.contributor.authorSilva, Pedro Honório da
dc.contributor.authorCouto, Pedro Almeida
dc.date.accessioned2026-11-23T09:12:49Z
dc.date.issued2025-01-01
dc.date.updated2026-11-20T15:43:03Z
dc.description.abstractClinical relevance Assessing visual and cognitive performance in athletes is important for optimising training strategies and preventing visual strain in both esports and traditional sports. Background This study compared visual acuity, refractive error, binocular functions, and cognitive perception measures between esports and soccer players to optimise visual performance strategies. Methods Twenty-eight male esports athletes and 38 male soccer players were assessed. Visual acuity was measured using an ETDRS chart, and refractive error was assessed with retinoscopy. Phoria was evaluated with the Modified Thorington Technique at distance and near. Fusional vergence ranges and vergence facility were measured using prism bars and a prism flipper. Monocular accommodative facility at near was tested with ± 2.00D flipper lenses. Stereopsis was assessed using the Randot Stereo Test. Perception span, multiple object tracking, and visual reaction time, were evaluated using the Senaptec Sensory Station. Results Soccer players had significantly better visual acuity than esports athletes. For the right eye, the soccer group had an average decimal visual acuity of 1.1 ± 0.2 compared to 0.9 ± 0.1 in the esports group (p < 0.001). Refractive error analysis showed that esports athletes had more myopia (M =-0.67 ± 1.70D) and higher astigmatism (J0 = 0.47 ± 0.53D) than soccer players (M = 0.6 ± 1.06D, J0 = 0.09 ± 0.43D; p < 0.001). Soccer players demonstrated better negative fusional vergence at distance (p = 0.049) and superior near-accommodative facility (12.4 ± 4.2 cpm vs. 9.4 ± 5.2 cpm; p = 0.025). Soccer players also outperformed esports athletes in multiple object tracking (1811.3 ± 391.3 vs. 1523.4 ± 528.7; p = 0.013). No significant differences were observed in stereopsis or other binocular vision parameters. Conclusion Soccer players showed superior visual acuity and performance in tasks such as negative fusional vergence and near-accommodative facility compared to esports players. Esports athletes had more myopia and astigmatism, indicating a need for targeted visual interventions. fusional vergence and near-accommodative facility compared to esports players. Esports athletes had more myopia and astigmatism, indicating a need for targeted visual interventions.eng
dc.description.sponsorshipThis work was supported by the Portuguese Foundation for Science and Technology (FCT) in the framework of the Strategic Funding UIDB/04650/2020.
dc.distributionnational
dc.identifier.citationJorge, J., Cymbron, F., da Silva, P. H., & Almeida Couto, P. (2024). Comparative analysis of visual and cognitive performance in esports athletes and soccer players. Clinical and Experimental Optometry, 108(7), 838–843. https://doi.org/10.1080/08164622.2024.2430637
dc.identifier.doi10.1080/08164622.2024.2430637
dc.identifier.eissn1444-0938
dc.identifier.issn0816-4622
dc.identifier.pmc39618292
dc.identifier.urihttps://hdl.handle.net/1822/104831
dc.language.isoeng
dc.peerreviewedyes
dc.publisherTaylor and Francis
dc.relationPhysics Center of Minho and Porto Universities [UIDB/04650/2020]
dc.relation.hasversionhttps://www.tandfonline.com/doi/full/10.1080/08164622.2024.2430637
dc.rightsrestrictedAccess
dc.subjectBinocular vision
dc.subjectesports
dc.subjectrefractive error
dc.subjectsoccer players
dc.subjectsports vision
dc.subjectvisual performance
dc.titleComparative analysis of visual and cognitive performance in esports athletes and soccer playerseng
dc.typearticle
dspace.entity.typePublication
oaire.awardNumberUIDB/04650/2020
oaire.awardTitlePhysics Center of Minho and Porto Universities [UIDB/04650/2020]
oaire.awardURIhttps://hdl.handle.net/1822/97590
oaire.citation.endPage843
oaire.citation.issue7
oaire.citation.startPage838
oaire.citation.volume108
oaire.citationEndPage843
oaire.citationIssue7
oaire.citationStartPage838
oaire.citationVolume108
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.fundingStreamConcurso de avaliação no âmbito do Programa Plurianual de Financiamento de Unidades de I&D (2017/2018) - Financiamento Base
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
relation.isProjectOfPublicationf50575ae-b9b2-4c69-9510-aad351d38ff5
relation.isProjectOfPublication.latestForDiscoveryf50575ae-b9b2-4c69-9510-aad351d38ff5
sdum.export.identifier18705
sdum.journalClinical and Experimental Optometry

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
COMPAR~1.PDF
Tamanho:
675.3 KB
Formato:
Adobe Portable Document Format