Personalized dynamic phantom of the right and left ventricles based on patient-specific anatomy for echocardiography studies — Preliminary results

dc.contributor.authorFonseca, João Luís Gomespor
dc.contributor.authorMorais, Pedro André Gonçalvespor
dc.contributor.authorQueirós, Sandro Filipe Monteiropor
dc.contributor.authorVeloso, Fernandopor
dc.contributor.authorPinho, Antonio C. M.por
dc.contributor.authorFonseca, Jaime C.por
dc.contributor.authorCorreia-Pinto, Jorgepor
dc.contributor.authorVilaça, João L.por
dc.date.accessioned2019-01-15T11:49:39Z
dc.date.available2019-01-15T11:49:39Z
dc.date.issued2018-05
dc.description.abstractDynamic phantoms of the heart are becoming a reality, with their use spread across both medical and research fields. Their purpose is to mimic the cardiac anatomy, as well as its motion. This work aims to create a dynamic, ultrasound-compatible, realistic and flexible phantom of the left and right ventricles, with application in the diagnosis, planning, treatment and training in the cardiovascular field for studies using echocardiography. Here, we focus on its design and production with polyvinyl alcohol cryogel (PVA-C), to be assembled with a pump and an electromechanical (E/M) system in a water tank. Based on a patient-specific anatomical model and produced using a 3D printing technique and molding, the PVA-C phantom mimics the ventricles' natural anatomy and material properties, while the pump and E/M systems mimic the natural movements and pressures. The PVA-C phantom was assessed by imaging and measuring it using a four-dimensional ultrasound machine. The PVA-C phantom demonstrated to be a versatile option to produce patient-specific biventricular models, preserving their shape after manufacturing and presenting good echogenic properties. Both chambers were clearly seen in the ultrasound images, together with the interventricular septum and the myocardial wall. Automated left ventricle measures revealed a decrease of its volume with regard to the designed model (98 ml to 74 ml). Overall, the preliminary results are satisfactory and encourage its use for the abovementioned purposespor
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.description.sponsorshipFEDER funds through the Competitiveness Factors Operational Programme (COMPETE), and by National funds through the Foundation for Science and Technology (FCT) under the project POCI -01-0145-FEDER-007038 and EXPL/BBB-BMD/2473/2013, and by the projects NORTE-01-0145-FEDER-000013 and NORTE-01-0145-FEDER-024300, supported by the NORTE 2020, under the Portugal 2020 Partnership Agreement, through the European Regional Development Fund (FEDER). J. Gomes-Fonseca, P. Morais, S. Queirós, and F. Veloso were funded by FCT under the Ph.D. grants PD/BDE/113597/2015, SFRH/BD/95438/2013, SFRH/BD/93443/2013, and SFRH/BD/131545/2017por
dc.distributioninternationalpor
dc.identifier.citationGomes-Fonseca, J., Morais, P., Queirós, S., Veloso, F., Pinho, A. C., Fonseca, J. C., ... & Vilaça, J. L. (2018, May). Personalized dynamic phantom of the right and left ventricles based on patient-specific anatomy for echocardiography studies—Preliminary results. In 2018 IEEE 6th International Conference on Serious Games and Applications for Health (SeGAH) (pp. 1-7). IEEEpor
dc.identifier.doi10.1109/SeGAH.2018.8401362por
dc.identifier.eisbn978-1-5386-6298-4
dc.identifier.eissn2573-3060
dc.identifier.isbn978-1-5386-6299-1
dc.identifier.issn2330-5649por
dc.identifier.urihttps://hdl.handle.net/1822/58201
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherIEEEpor
dc.relationinfo:eu-repo/grantAgreement/FCT/5876-PPCDTI/135498/PTpor
dc.relation.publisherversionhttps://ieeexplore.ieee.org/abstract/document/8401362por
dc.rightsopenAccesspor
dc.subjectPatient-specificpor
dc.subjectPhantompor
dc.subjectPVA-Cpor
dc.subjectManufacturingpor
dc.subjectEchocardiographypor
dc.subject.fosCiências Médicas::Medicina Básicapor
dc.subject.fosCiências Médicas::Biotecnologia Médicapor
dc.subject.fosCiências Naturais::Ciências da Computação e da Informaçãopor
dc.subject.wosScience & Technologypor
dc.titlePersonalized dynamic phantom of the right and left ventricles based on patient-specific anatomy for echocardiography studies — Preliminary resultspor
dc.typeconferencePaperpor
dspace.entity.typePublicationen
oaire.citationConferencePlaceVienna, Austriapor
oaire.citationEndPage7por
oaire.citationStartPage1por
sdum.conferencePublication2018 IEEE 6th International Conference on Serious Games and Applications for Health, SeGAH 2018por
sdum.journalIEEE International Conference on Serious Games and Applications for Healthpor