Clinical performance and “ex vivo” dehydration of silicone hydrogel contact lenses with two new multipurpose solutions

dc.contributor.authorGonzález-Méijome, José Manuel
dc.contributor.authorda Silva, Ana Carla
dc.contributor.authorNeves, Helena
dc.contributor.authorLopes-Ferreira, Daniela
dc.contributor.authorQueirós, António
dc.contributor.authorJorge, Jorge
dc.date.accessioned2012-11-07T11:23:56Z
dc.date.available2012-11-07T11:23:56Z
dc.date.issued2013
dc.date.submitted2012-06-07
dc.description.abstractPURPOSE: To compare the performance of two novel multipurpose disinfecting solutions (MPDS) in preventing silicone hydrogel contact lens dehydration, provide higher scores of subjective comfort and stable optical quality during a month of lens wear in neophyte volunteers. METHOD: This is a prospective, double-blind, contralateral and randomised study involving the contra lateral use of Complete RevitaLens(®) and Biotrue MPDS. Twenty-five neophytes wore Air Optix Aqua for 1 month. Volunteers were evaluated on day 1 and day 30 at 2 and 10h after lens insertion. Tear film stability using Tearscope Plus (Keeler, UK), whole eye aberrations for 4.5mm pupil size (IRx3, ImaginEyes, France) and subjective comfort (0-10 score) along with the dehydration values obtained with a gravimetric method were collected at each follow-up visit. RESULTS: NIBUT values decreased significantly with both care systems from baseline to 10h visit on day 1 (p=0.032 and 0.016, mean difference=-6.7s and -7.0s, for Complete Revitalens and Biotrue, respectively). Dehydration rates and ocular aberrations did not change significantly over the month of follow-up (p>0.05, ANOVA with Bonferroni post hoc corrections), nor between visits within the same day (p>0.05, paired sample T-test). End-of-day dryness sensation worsened similarly with both MPDS after 1 month (p=0.021 and 0.005, mean difference=-1.4 and -1.3, for Complete Revitalens and Biotrue, respectively). CONCLUSIONS: Regardless of their different chemical compositions in terms of moisture additives both MPDS solutions evaluated performed similarly regarding objective measures of dehydration, tear stability and optical quality but presented significant differences in subjective symptoms.por
dc.description.sponsorshipAMO Germany GmbH. Tpor
dc.distributioninternationalpor
dc.identifier.doi10.1016/j.clae.2012.10.071por
dc.identifier.issn1367-0484por
dc.identifier.pmid23108008por
dc.identifier.urihttps://hdl.handle.net/1822/20705
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.relation.publisherversionhttp://linkinghub.elsevier.com/retrieve/pii/S1367-0484(12)00278-0por
dc.rightsopenAccesspor
dc.subjectContact lenspor
dc.subjectMultipurpose solutionspor
dc.subjectMPDSpor
dc.subjectContact lens carepor
dc.subjectDehydrationpor
dc.subjectComfortpor
dc.subjectDrynesspor
dc.subject.wosScience & Technologypor
dc.titleClinical performance and “ex vivo” dehydration of silicone hydrogel contact lenses with two new multipurpose solutionspor
dc.typearticlepor
dspace.entity.typePublicationen
oaire.citationEndPage92por
oaire.citationIssue2por
oaire.citationStartPage86por
oaire.citationTitleContact Lens & Anterior Eyepor
oaire.citationVolume36por
sdum.journalContact Lens and Anterior Eyepor
sdum.publicationstatuspublishedpor