The influence of lens material and lens wear on the removal and viability of staphylococcus epidermidis

dc.contributor.authorSantos, Lívia
dc.contributor.authorRodrigues, Diana Alexandra Ferreira
dc.contributor.authorLira, Madalena
dc.contributor.authorOliveira, M. Elisabete
dc.contributor.authorOliveira, Rosário
dc.contributor.authorYebra-Pimentel Vilar, Eva
dc.contributor.authorAzeredo, Joana
dc.date.accessioned2008-07-02T20:57:12Z
dc.date.available2008-07-02T20:57:12Z
dc.date.issued2008-06
dc.description.abstractPurpose: The aim of this study was to evaluate the influence of lens material and lens wear on the removal capability of Staphylococcus epidermidis. Assessment of viability of remaining adhered bacteria was another goal of this work. Four silicone hydrogel materials (galyfilcon A, balafilcon A, lotrafilcon A, lotrafilcon B) and one conventional hydrogel material (etafilcon A) were assayed. Methods: Detachment studies on S. epidermidis were carried out in a parallel plate flow chamber. Contact lenses (CLs) were fitted to the bottom of the flow chamber and a bacterial suspension was perfused into the system, promoting bacterial adhesion. Afterwards, detachment was stimulated using a multipurpose solution (MPS, ReNu Multiplus®) and the percentage of removed bacteria estimated through microscopic observation and enumeration. Remaining adhered bacteria were stained with propidium iodide (PI) and enumerated in order to assess their viability. Additionally, the worn lenses were observed by confocal laser scanning microscopy (CLSM) to visualize bacterial distribution along the lens surfaces. Results: Bacterial removal was significant ( p < 0.05) for both unworn and worn galyfilcon A and etafilcon A. Galyfilcon A exhibited a detachment percentage of 59.1 and 63.5 while etafilcon A of 62.6 and 69.3, both for unworn and worn lenses, respectively. As far as bacterial viability is concerned, it was found that worn lenses exhibit a superior amount of non-viable bacteria than unworn CLs. Images obtained by CLSM revealed an irregular bacterial distribution for all lens materials. Conclusions: It appears that surface and/or bulk structure of the lens material affects removal of S. epidermidis while CL wear influences their viability.eng
dc.description.sponsorshipFundação para a Ciência e a Tecnologia (FCT)por
dc.distributioninternationalpor
dc.identifier.citation"Contact Lens & Anterior Eye". ISSN 1367-0484. 31:3 (Jun. 2008) 126-130.eng
dc.identifier.doi10.1016/j.clae.2008.01.003por
dc.identifier.issn1367-0484eng
dc.identifier.pmid18314377por
dc.identifier.urihttps://hdl.handle.net/1822/7944
dc.language.isoengeng
dc.peerreviewedyeseng
dc.publisherElseviereng
dc.rightsopenAccesseng
dc.subjectBacterial detachmenteng
dc.subjectSilicone hydrogeleng
dc.subjectCell viabilityeng
dc.titleThe influence of lens material and lens wear on the removal and viability of staphylococcus epidermidiseng
dc.typearticlepor
dspace.entity.typePublicationen
oaire.citationEndPage130por
oaire.citationIssue3por
oaire.citationStartPage126por
oaire.citationVolume31por
sdum.journalContact Lens and Anterior Eyepor
sdum.number3eng
sdum.pagination126-130eng
sdum.publicationstatuspublishedeng
sdum.volume31eng