Engineering simulations of a super-complex cultural heritage building: Ica Cathedral in Peru

dc.contributor.authorCiocci, Maria Piapor
dc.contributor.authorSharma, Satyadhrikpor
dc.contributor.authorLourenço, Paulo B.por
dc.date.accessioned2019-01-14T23:55:54Z
dc.date.available2019-01-14T23:55:54Z
dc.date.issued2018-05-01
dc.date.updated2019-01-14T20:01:29Z
dc.description.abstractThe Cathedral of Ica, Peru, is one of the four prototype buildings involved in the ongoing Seismic Retrofitting Project, initiative of the Getty Conservation Institute. The complex historical building, which was heavily damaged by earthquakes in 2007 and 2009, can be divided into two substructures: an external masonry envelope and an internal timber frame built by a construction method known as quincha technique. This study makes use of the information available in literature and the results obtained from experimental campaigns performed by Pontificia Universidad Catlica del PerA and University of Minho. Nonlinear behaviour of masonry is simulated in the numerical models by considering specified compressive and tensile softening behaviour, while isotropic homogeneous and linear behaviour is adopted for modelling timber with appropriate assumptions on the connections. A single representative bay was initially studied by performing linear elastic analysis and verifying the compliance with the various criteria specified by the applicable normative to discuss the actual failure of Ica Cathedral. Afterwards, the structural behaviour of the two substructures composing the Cathedral is evaluated independently. Finally, the interaction of these two substructures is investigated by performing structural analysis on the entire structure of Ica Cathedral. Several structural analysis techniques, including eigenvalue, nonlinear static and dynamic analyses, are performed in order to: (1) evaluate the dominant mode shapes of the structure; (2) validate the numerical models by reproducing the structural damage observed in situ; (3) estimate the structural performance; and (4) identify the main failure mechanisms.por
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.description.sponsorshipThis work was carried out with funding from the Getty Seismic Retrofitting Project under the auspices of the Getty Conservation Institute (GCI). This work is also partially financed by FEDER funds through the Competitivity Factors Operational Programme-COMPETE and by national funds through FCT-Foundation for Science and Technology within the scope of the projects POCI-01-0145-FEDER-007633 and PTDC/ECM-EST/2777/2014.por
dc.distributioninternationalpor
dc.identifier.doi10.1007/s11012-017-0720-3por
dc.identifier.issn0025-6455por
dc.identifier.urihttps://hdl.handle.net/1822/58188
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherSpringerpor
dc.relationPTDC/ECM-EST/2777/2014por
dc.rightsopenAccesspor
dc.subjectUnreinforced masonry buildingpor
dc.subjectQuincha-adobe systempor
dc.subjectFinite element (FE) modellingpor
dc.subjectNonlinear analysispor
dc.subjectSafety assessmentpor
dc.subject.wosScience & Technology
dc.titleEngineering simulations of a super-complex cultural heritage building: Ica Cathedral in Perupor
dc.typearticle
dspace.entity.typePublicationen
oaire.citationEndPage1958por
oaire.citationIssue7por
oaire.citationStartPage1931por
oaire.citationVolume53por
sdum.export.identifier5246
sdum.journalMeccanicapor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
CiocciSharmaLoureno_Engineeringsimulationsofasuper-complexculturalheritagebuildingIcaCathedralinPeru.pdf
Tamanho:
2.26 MB
Formato:
Adobe Portable Document Format