Experimental and analytical assessment of the capacity of traditional single notch joints and impact of retrofitting by self-tapping screws

dc.contributor.authorSobra, Karelpor
dc.contributor.authorde Rijk, Richardpor
dc.contributor.authorAktas, Yasemin D.por
dc.contributor.authorAvez, Coraliepor
dc.contributor.authorBurawska, Isabelapor
dc.contributor.authorBranco, Jorge M.por
dc.date.accessioned2020-08-04T14:55:15Z
dc.date.available2020-08-04T14:55:15Z
dc.date.issued2016
dc.date.updated2020-08-04T14:23:50Z
dc.description.abstractThe joints are the most crucial parts of a timber building and determine the overall structural behaviour, load-bearing capacity and failure mechanisms. Therefore, keeping the joints fully functional is of utmost importance to ensure a desired structural performance of timber buildings under various actions. Since replacement of damaged parts of an existing structure is expensive and in many cases very difficult to perform in situ, retrofitting to avoid failure becomes an increasingly widespread strategy. In this paper, the capacity and failure mechanisms of single notch joints before and after a simple retrofitting intervention by means of self-tapping screws were investigated. To this end, a series of tests were carried out during the 5th COST FP 1101 Training School, held in University of Minho, Portugal. The joints were first tested under compression, and the load-bearing capacity values obtained at the end of tests were compared to the capacity values calculated using theoretical models proposed in a variety of national codes. Then, tested joints were retrofitted using self-tapping screws. The retrofitting strategy aimed to prevent failure mechanism that was shown to dominate joints' behaviour in the unreinforced state, rather than to increase the load-bearing capacity or stiffness. The impact of retrofitting on the joints' performance was discussed and the success of the proposed intervention was further debated.por
dc.description.sponsorship- The authors are grateful to COST Action for funding the FP1101 and RILEM 245 Training School at University of Minho in Guimaraes, Portugal, and to Dr. Jorge M. Branco and other members of Civil Engineering Department for making this study possible.por
dc.distributioninternationalpor
dc.identifier.doi10.1007/978-3-319-39492-3_30por
dc.identifier.eisbn978-3-319-39492-3por
dc.identifier.isbn978-3-319-39491-6por
dc.identifier.issn2366-2557
dc.identifier.urihttps://hdl.handle.net/1822/66271
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherSpringer International Publishing AGpor
dc.relation.publisherversionhttps://link.springer.com/chapter/10.1007/978-3-319-39492-3_30por
dc.rightsopenAccesspor
dc.subjectTraditional carpentry jointspor
dc.subjectSingle notch jointspor
dc.subjectRetrofittingpor
dc.subjectSelf-tapping screwspor
dc.subject.wosScience & Technology
dc.titleExperimental and analytical assessment of the capacity of traditional single notch joints and impact of retrofitting by self-tapping screwspor
dc.typeconferencePaperpor
dspace.entity.typePublicationen
oaire.citationEndPage369por
oaire.citationStartPage359por
oaire.citationVolume1
sdum.bookTitleHISTORICAL EARTHQUAKE-RESISTANT TIMBER FRAMING IN THE MEDITERRANEAN AREA
sdum.conferencePublicationHistorical Earthquake-Resistant Timber Framing in the Mediterranean Areapor
sdum.event.typeconferencepor
sdum.export.identifier5788
sdum.journalLecture Notes in Civil Engineering

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
20151028_PAPER_Karel3.pdf
Tamanho:
4.46 MB
Formato:
Adobe Portable Document Format